SAFETY RULES
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.
Voltage
Minimum Safe
Phase to Phase
Approach Distance
Feet
 Meters
0 to 300V
Avoid Contact
300V to 50KV
10
3.05
50KV to 200KV
15
4.60
200KV to 350KV
20
6.10
350KV to 500KV
25
7.62
500KV to 750KV
35
10.67
750KV to 1000KV
45
13.72
Allow for platform movement, electrical line sway
or sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Maximum capacity
ANSI and CSA  models
500 lbs
227 kg
CE and Australia models
440 lbs
200 kg
Maximum occupants
2
Do not raise the boom unless the machine is level.
Do not set the machine up on a surface where it
cannot be leveled using only the outriggers.
Do not raise the boom unless all four outriggers
are lowered, the footpads are in firm contact with
the ground and the machine is level.
Do not set the machine up unless it is on a firm
surface.  Avoid drop-offs, holes, unstable or
slippery surfaces and other possible hazardous
conditions.
Do not move the machine when the boom is
raised.
Do not adjust or stow the outriggers when the
boom is raised.