Behringer Xenyx X1222USB 사용자 설명서

다운로드
페이지 16
14
XENYX X1222USB User Manual
Channels 9/10, 11/12
Stereo line inputs
Type 
2 x ¼" TRS connector, unbalanced
Impedance 
approx. 40 kΩ @ 0 dB Gain
Gain range 
-20 dB to +20 dB
Max. input level 
+22 dBu @ 0 dB Gain
CD/Tape In
Type 
RCA connectors
Impedance 
approx. 10 kΩ
Max. input level 
+22 dBu
EQ Mono Channels
Low 
80 Hz / ±15 dB
Mid 
2.5 kHz / ±15 dB
High 
12 kHz / ±15 dB
Low cut 
80 Hz, 18 dB/oct.
EQ Stereo Channels
Low 
80 Hz / ±15 dB
Mid 
2.5 kHz / ±15 dB
High 
12 kHz / ±15 dB
MON/FX Send 
Type 
¼" TS connector, unbalanced
Impedance 
approx. 120 Ω 
Max. output level 
+22 dBu
Aux Returns
Type 
¼" TRS connector, unbalanced
Impedance 
approx. 10 kΩ
Max. input level 
+22 dBu
Main Outputs
Type 
XLR, electronically balanced
Impedance 
approx. 240 Ω balanced 
approx. 120 Ω unbalanced
Max. output level 
+28 dBu
Headphone Output
Type 
¼" TRS connector, unbalanced
Max. output level 
+19 dBu / 150 Ω (+25 dBm)
CD/Tape Out
Type 
RCA connectors
Impedance 
approx. 1 kΩ
Max. output level 
+22 dBu
DSP 
Texas Instruments
Converter 
24-bit Sigma-Delta 
64/128-times oversampling
Sampling rate 
40 kHz
USB
Audio 
Stereo In/Out
Connector 
Type B
Converter 16-bit
Sample Rate 
48 kHz
Main Mix System Data
Noise
Main mix @ -∞,  
-99 dB 
Channel fader -∞ 
-101 dB A-weighted
Main mix @ 0 dB, 
-84 dB 
Channel fader -∞ 
-87 dB A-weighted
Main mix @ 0 dB, 
-80 dB 
Channel fader @ 0 dB 
-82 dB A-weighted
Power Supply
Mains Voltage 
100 - 240 V~, 50 - 60 Hz
Power consumption 
40 W
Fuse 
T  1.6 A  H 250 V
Mains connection 
Standard IEC receptacle
Physical
Dimensions (W x D x H) 
approx. 14.56 x 13 x 3.54" 
approx. 370 x 330 x 90 mm
Weight (net) 
approx. 9.3 lbs. 
approx. 4.22 kg 
Measuring conditions:
1:  1 kHz rel. to 0 dBu; 20 Hz - 20 kHz; line input; main output; unity gain.
2:  20 Hz - 20kHz; measured at main output. Channels 1 - 4 unity gain; EQ flat; all channels on main mix; 
channels 1/3 as far left as possible, channels 2/4 as far right as possible. Reference = +6 dBu.
BEHRINGER is constantly striving to manintain the highest professional standards. As a result of these efforts, 
modifications may be made from time to time to existing products without prior notice. Specifications and 
appearance may differ from those listed or illustrated.