Electrical Connections 
 
All electrical wiring and connections must be in accordance with the National 
Electric Code ANSI/NFPA No. 70 (latest edition), or the Canadian Electrical Code 
C22.1 (latest edition) and any local codes which may apply. The water heater 
must be electrically grounded. 
 
If a flexible line cord and plug is permitted by local code, then provide a (3) three 
wire grounding type receptacle within 6 feet (1.9 m) of the water heater and use 
the flexible cord provided. Do not plug the line cord into a receptacle that can 
have its power supply interrupted by a switch that is used to turn on and off 
lights. 
 
If wiring in conduit is required, remove the flexible line cord from the jacket and 
install a 1/2" electrical conduit connector and connect 110/120 volt power source.  
Connect the hot, neutral, and ground leads of the electrical supply to the 
corresponding locations that were connected to the flexible line cord. 
 
 
 
The wiring diagram for the 48 gal, 65,000 BTU (181.7 L, 19.1 Kw/Hr), 65 gal, 
65,000 BTU (246.1 L, 19.1 Kw/Hr) and 75 gal, 76,000 BTU input (283.9 L, 22.3 
Kw/Hr) models is located in Figure 11 on page 31.  The wiring diagram for 
the 40 gal, 40,000 BTU (151.4 L, 11.7 Kw/Hr) and 48 gal, 40,000 BTU (181.7 
L, 11.7 Kw/Hr) models are located in Figure 12 on page 32.  Refer to the 
rating plate located on the water heater for correct model identification.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CAUTION
 
Turn off or disconnect the electrical power supply to the water heater before 
servicing. Label all wires prior to disconnection when servicing controls.   
Wiring errors can cause improper and dangerous operation.  Verify proper 
operation after servicing.
 