Problem 
Cause 
Solution 
The compressor runs for 1 to 5 
minutes and stops. 
The voltage is not in the 
correct range. 
Switch off the power and restart 
when the power is normal. 
 
The compressor runs but the 
inner liner does not get very 
cold. 
The ambient temperature 
is too high. 
 
The operating temperature of this 
unit is <90F. If temperature is 
higher than 90F, the unit need 
longer to cool to the set 
temperature. 
The system is blocked. 
Contact service department via 
email at service@whynter.com 
 
 
 
 
The inner liner is very cold and 
the compressor runs 
continuously. 
The ice layer on the 
evaporator is too thick. 
Defrost the freezer 
The door is being opened 
and closed too frequently. 
The door should be opened as little 
as possible. 
The freezer is overloaded. 
Remove some products from the 
freezer. 
The condenser is not well-
ventilated.  
Place the freezer in  a well-
ventilated place. 
The temperature sensor- 
tube is out of the 
evaporator or the controller 
is faulty. 
Contact service department via 
email at service@whynter.com 
 
 
The compressor does not run. 
The controller is faulty (the 
power indicator is not on). 
Contact service department via 
email at service@whynter.com 
The thermostat is set too 
high and the ambient 
temperature is too low. 
 
Set the freezer to a lower 
temperature. 
The freezer is noisy. 
The freezer is not level. 
Place the freezer on a flat and hard 
surface. 
The voltage is not in the 
correct range. 
Switch off the power and restart 
when the power is normal. 
Can the unit plugged into both 
AC and DC power supply? 
 
Yes. If both AC and DC are plugged 
in at the same time, then the unit 
will primarily operate on AC. If the 
AC power source fails, DC will 
become primary source of power 
supply. 
 
TROUBLESHOOTING