White Rodgers 3049-115 Mercury Flame Sensors 제품 매뉴얼

다운로드
페이지 1
www.white-rodgers.com
79
FURNACE
MERCURY FLAME SENSORS
Prevent Gas Flow to Main Burner if Pilot Flame is Not Burning or Is
Insufficient to Properly Ignite Main Burner
FEATURES
• These sensors combine a rugged Snap-Action switch and powerful mercury
  actuated thermal element.
• May be used with natural, manufactured or mixed gases and with LP gases where
  means are provided for obtaining automatic pilot gas shut-off.
• Switch may be conveniently mounted in any position.
• Cover is easily removed, making switch terminals readily accessible.
• No button to depress – Sensors are recycling type which require relighting or
  possible restoration of proper gas pressure to return to operation.
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . .   Contacts close approximately 60 seconds
   
  after pilot is ignited; open approximately
   
  40 seconds after flame is extinguished
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   U.L. recognized and C.S.A. certified,
   
  A.G.A. design certified & C.G.A. certified
Dimensions. . . . . . . . . . . . . . . . . . . . . . . .  
2
3
/
4
H x 2

/
6
 W x 
7
/
8
D
 
Model 
Element 
Electrical Rating
 
Number 
Length 
120 VAC 
240 VAC 
30 VAC
 
3046-5
 
48” 
25 VA 
25 VA 
90 VA
PLUG-IN TYPE MERCURY FLAME SENSORS
Designed for use with White-Rodgers Diaphragm, “Cushioned Power” 
or “Silent Knight” Gas Valves having Plug-In Receptacle
FEATURES
• Plug-in feature requires no additional electrical connections or mounting devices.
• Sensor combines a rugged Snap-Action SPDT switch and powerful mercury
  actuated thermal element.
• May be used with natural, manufactured or mixed gases and with LP gases where
  means are provided for obtaining automatic pilot gas shut-off.
• No button to depress – Sensors are recycling type which require relighting or
  possible restoration of proper gas pressure to return to operation.
• The SPDT switch can energize ignitor circuit to relight pilot (as with roof top units).
SPECIFICATIONS
Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . .   Contacts close approximately 60 seconds
   
  after pilot is ignited; open approximately
   
  40 seconds after flame is extinguished
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   U.L. recognized, A.G.A. design certified
   
  and C.G.A. certified
 
Model 
Element 
Electrical Rating
 
Number 
Length 
120 VAC 
240 VAC 
30 VAC 
Comments
 
30A46-5
 
48” 
25 VA 
25 VA 
90 VA 
stud mount element
  30A46-105 
2” 
25 VA 
25 VA 
90 VA 
sleeve over element,
 
 
 
 
 
 
no stud mount
30A46-5
3046-5
GAS BURNER
CONTROLS