Application of this type of control may cause flame 
rollout on initial startup and could cause personal 
injury and/or property damage.
Check product specification and cross reference before 
replacing existing module. Do not use if existing module 
is not listed. Use of a program key other than listed can 
result in appliance malfunction. 
50E47-843
Universal Hot Surface Ignition Control
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL 
INJURY AND/OR PROPERTY DAMAGE.
CONTENTS
Description  ...................................................................  1
Precautions  ..................................................................  1
Specifications  ...............................................................  2
Installation  ....................................................................  2
 
Mounting & Wiring
Operation & Troubleshooting  ......................................... 4
 
 DESCRIPTION
PRECAUTIONS
The 50E47-843 is a universal replacement Hot Surface Ignition 
(HSI) control designed for maximum compatibility with existing 
systems. It features:
A card port and six program keys to select the 
  Trial for Ignition Time, Retries, Pre-purge and 
  Igniter Warm Up timings
.
•  A Jumper to accommodate systems using Direct 
  Sense (sensing through ignitor) or Indirect Sense 
  (using a Flame Sensor).
•  LED indicator for quick system and module diagnostics and
 troubleshooting. 
GENERAL PRECAUTION
!
Do not use on circuits exceeding specified voltage. 
Higher voltage will damage control and could cause 
shock or fire hazard.
Do not short out terminals on gas valve or primary 
control to test. Short or incorrect wiring will damage 
thermostat and could cause personal injury and/or 
property damage.
WARNING
!
To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.
Label all wires prior to disconnection when servicing 
controls. Wiring errors can cause improper and dan-
gerous operation.
This control is not intended for use in locations where 
it may come in contact with water. Suitable protection 
must be provided to shield the control from exposure 
to water (dripping, spraying, rain, etc.).
CAUTION
!
CAUTION
!
If in doubt about whether your wiring is millivolt, line, or low volt-
age, have it inspected by a qualified heating and air conditioning
contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled 
carefully. Rough handling or distorting components could cause 
the control to malfunction.