Bosch Appliances Video Game Controller d9412gv3 사용자 설명서

다운로드
페이지 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 53 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
CC# Enter Key Relay 
Default: 
Selection: 
0 to 128, A, B, C (0 to 64, A, B, C 
for the D7412GV3) 
The [ENTER] key is not used to 
activate a relay. 
1 to 128 (64), 
A, B, C 
Assign the relay number that 
activates when [ENTER] is pressed 
at this keypad after the user enters 
a valid passcode. 
 
Enter Key Relay: Program the relay number that 
activates momentarily for 10 sec when a user enters 
a valid passcode and presses the [ENTER] key on 
the keypad. Two events are generated when this 
function is used: RELAY ### SET with User ID, and 
RELAY ### RESET without User ID. The system 
logs this action as two events. 
  Entering a valid code and pressing [ENTER] at a 
keypad silences a ringing bell. 
  Using CC# Enter Key Relay for a low-level 
access control strike on a door does not shunt a 
point. 
 
 
When programmed to activate a relay, the 
[ENTER] key cannot be used for any 
other function. 
Relays used for this function must not be 
shared with any other point, sensor reset, 
control panel, or bell functions. Sharing 
can cause errors in relay operation. 
 
CC# Enter Key Cycle Door 
Default: 
No 
Selection:  Yes or No 
Yes 
The [ENTER] key is used to cycle the 
door programmed for CC Assign 
Door. 
No 
The [ENTER] key is not used to cycle 
the door. 
Enter Key Cycle Door: Program this prompt as Yes 
to start the door cycle sequence for the door number 
programmed in CC# Assign Door when a user 
enters a valid passcode and presses [ENTER]. This 
includes shunting the point assigned to the door. 
ACCESS GRANTED prints on the local printer and at 
the central station receiver, if programmed. 
 
 
  The service passcode cannot be used 
for the CC# Enter Key Cycle Door 
application. 
  When programmed to activate a relay, 
the [ENTER] key cannot be used for 
any other function. 
  Relays used for this function must not 
be shared with any other point, sensor 
reset, control panel, or bell functions. 
Sharing can cause errors in relay 
operation. 
  The door does not cycle if Enter Key 
Relay is programmed. 
  9210 NOT READY appears at this 
keypad when you press [ENTER] if the 
D9210B is not programmed with a D# 
Entry Area
 (in the Access Control 
section) or if CC Assign Door does not 
have a door number assigned. 
 
CC# Assign Door 
Default: 
No Door 
Selection:  No Door, 1 to 8 on D9412GV3. 
(No Door, 1, 2 on D7412GV3) 
No 
Door 
No door controller is assigned for adding 
tokens. 
1 to 8 The door controller assigned to this keypad 
is used to read new tokens when the Add 
User Mode is initiated.  
If the assigned door remains open and this keypad 
has the CC# Close Door Warning Tone set to Yes
the CLOSE DOOR # message appears on this 
keypad.