Connect White Tube from TANK Port on RO Module to the Tank
Position tank in desired location.  Stand it upright or lay it  on its 
side (using the black plastic stand).  Measure the white tube from 
the RO module port  marked TANK  over to the tank and cut it to 
desired length.
Insert the white 1/4” tube through tank valve compression nut.  
Place 1/4” plastic insert in tubing.  Push tubing into valve.  Hand 
tighten the compression nut securely, and add 1/4 turn with a 
wrench.
Step 22
White Tube Connection
 
 
 
 
 
 
 
 
Step 19
Step 21
Step 20
                        Adapta Valve 
Remove a brass nut, plastic  sleeve and brass insert from the parts 
bag.  Place nut on  the tube fi rst, then the sleeve (Small taper end 
of sleeve must point to the end of tube) and then insert the brass 
insert into the end of the tube. 
Insert the white tube into the ¼” opening on the adapta valve until 
it stops.  Slide  nut and sleeve down and thread onto the male pipe 
threads.  Use a ½” wrench to securely tighten.  Run the tube to 
the inlet on the back of the RO system.  Leave enough tube so it 
is not kinked and cut the tube to desired length.
Note:  The white tube will be cut into two pieces.  One for the 
inlet and one for the tank.
Connect White Tube from Adapta Valve to IN Port on RO 