198
Setup for the Whole System
• When making DME settings for SWR2 (the second switcher), for the 
first DME, select [DME3] in the <1st DME> group. Turn all buttons in 
the <2nd DME> group off.
Setup in “Dual Simul” mode
When the system operation mode (see page 196) is set to “Dual Simul,” the 
following setting is required for setup of the two switchers and connected DME 
units.
In the <Setup Target> group, set the [System 1] or [System 2] button to ON, 
then carry out the setup. You can also set both to ON, and make the settings 
simultaneously on the two systems.
Setting the Signal Format and Screen Aspect Ratio 
(Format Menu)
To set the format, that is, the frame frequency and number of scan lines handled 
by each device, and the screen aspect ratio, use the System>Format menu.
To display the Format menu
In the Engineering Setup menu, select VF1 ‘System’ and HF3 ‘Format.’
Note
After changing any of the following settings, be sure to press [Execute] to save 
the new values. If you want to cancel the setting changes without saving them, 
press [Clear].
Note that since the [Execute] button is in the System>Format menu, when you 
make settings in a submenu, it is essential to remember to return to the 
System>Format menu and press the [Execute] button to save.
Setting the signal format
Use the following procedure.
1
In the <Frame/Field Rate> group of the System>Format menu, select the 
system operating frequency.
For more details, see “System Setup” in Chapter 1 (Volume 1).
2
Press the [Active Line/Aspect].
The Active Line/Aspect menu appears.
The status area shows the number of active scan lines and screen aspect 
ratio for the switcher and connected DME(s).