Setup Relating to Switcher Processor
  
Ch
apt
er 16 
E
ngin
eering Se
tup
2
Select the M/E you want to logically set to the PGM/PST from the 
<Logical M/E to Physical P/P> group.
P/P: assign the physical PGM/PST as logical PGM/PST.
M/E-1: assign the physical PGM/PST as logical M/E-1.
M/E-2: assign the physical PGM/PST as logical M/E-2.
M/E-3: assign the physical PGM/PST as logical M/E-3.
Signal Input Settings (Input Menu)
For setup relating to signal inputs, use the Switcher>Input menu.
To display the Input menu
In the Engineering Setup menu, select VF3 ‘Switcher’ and HF2 ‘Input.’
The status area shows source numbers and source names, input signal phase, 
and through mode on/off setting.
Making phase adjustment and through mode settings
Use the following procedure.
1
In the Switcher>Input menu, select the input signal to which the settings 
apply.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob to make the setting.
The selected input signal appears in reverse video.
2
Press [Input Phase Adj].
3
To adjust the phase, adjust the following parameter.
Knob
Parameter
Adjustment
Setting values
1
Src No
Input signal selection
1 to 80
Knob
Parameter
Adjustment
Setting values
2
Phase
Input signal phase
16 to +16