Faber Genie M1024 사용자 설명서

다운로드
페이지 127
56    Operational Reference 
Genie Monochrome Series-GigE Vision Camera 
Output Control via Sapera LT or GenICam Applications 
 
Sapera
 
Genie Sapera parameters for Strobe and General Outputs. 
See 
"
.  
OutputSelectorOutput_x = {Open = 0, Close = 1, Strobe On: Start of Exposure = 2, Pulse On: 
Valid Trigger = 4, Pulse On: Invalid Trigger = 5, Pulse On: Start of Readout = 6, Pulse On: End 
of Readout = 7, Pulse On: End of Acquisition = 8, Pulse On: Input 1 = 9, Pulse On: Input 2 = 10}
PulseDelayOutput_x = Delay in µs to assert pulse output 
PulseDurationOutput_x = Pulse duration in µs 
PolarityOutput_x = {Active Close = 0, Active Open = 1} 
 
 
 
GenICam features for Strobe and General Outputs: 
OutputLineSelector = Index to select output line {output 1 = 0, output 2 = 1}  
OutputLineMode = {SoftwareDriven = 0, EventDriven = 1} 
OutputLineEventSource = Event generating output line pulse {StartOfTrigger=0, 
StartOfExposure=1, EndOfExposure=2, StartOfReadout=3, EndOfReadout=4, 
EndOfAcquisition=5, EventOnInputLine1=6, EventOnInputLine2=7, OverTrigger=8,  
OutputLinePulsePolarity = State of output opto-coupler {Active Close = 0, Active Open = 1} 
OutputLinePulseDelay = Delay in µs to assert pulse output (range 0 to 64k) 
OutputLinePulseDuration = Pulse duration in µs (range 0 to 64k) 
OutputLineValue = static output state {Open = 0, Close = 1} 
 
Genie Processing Features 
The Genie monochrome series of cameras support a number of functions to enhance acquisitions or perform real 
time processing. Functions can be combined to solve specific imaging situations. The user can enable and evaluate 
each operation by using CamExpert.  
Lookup Table (LUT) 
The Genie camera includes a user programmable LUT as a component of its embedded processing features. The 
LUT is used for operations such as gamma adjustments, invert and threshold processes. CamExpert has a number of 
built in LUT operations for the user to explore (see 
). 
For monochrome sensors, the LUT table is a single 8-bit or 10-bit LUT (8/10-bit in, 8/10-bit out) as illustrated in 
the following figure. Pixel data when read out of the sensor is passed through the LUT memory array, where the 
new programmed pixel value is then passed to the Genie output circuit. The LUT data table is stored along with 
other parameters with the user configuration function (see 
).