G- and K-Series User’s Guide
 
8-14
The system confirms that you want to make the change. 
6
Select Yes and press Enter to make the change.
Changing the Additional SEP Settings
You can change four additional SEP settings:
!
Polling interval—This is the interval, in seconds, that the controller polls the 
SEPs for status changes. The default setting is 5 seconds.
!
Temperature sensor—This controls whether the controller’s onboard 
temperature sensor provides temperature information to the host along with the 
enclosure’s temperature detected by the SEP. The default setting is OFF, which 
means that neither the controller nor the enclosure is providing temperature 
information to the host.
!
Slot update status (Slot Flags)—This controls whether the controller sends 
commands to the SEP to update the status of each enclosure slot. The default 
setting is ON, which means that the controller does request status updates from 
the enclosure.
!
Enclosure update status (Global Flags)—This controls whether the controller 
sends commands to the SEP to update the overall status of the enclosure. The 
default setting is OFF, which means that the controller does not request status 
updates from the enclosure.
To change the SEP settings:
1
From the System Menu, select Configuration Menu and press Enter.
The Configuration Menu screen displays.
2
Select SEP Configuration and press Enter.
The SEP Configuration screen displays.
Keep the same LUN for the SEP at 
all times
!
Select the [LUN] you want to use 
and press Enter.
This can be any number from 0 to 
7 that is not already in use.
To
Do this