302 VT1422A Command Reference  
INPut
INPut:LOW?
INPut:LOW? (@<channel>) 
returns the LO input configuration for the channel 
specified by <channel>. This command is for strain SCPs only, not for VT1529A/B.
Parameters
Comments
The <channel> parameter must specify a single channel only.
Returned Value: Returns FLO or WV. The data type is string.
Related Commands: INP:LOW
Send with VXIplug&play Function: hpe1422_cmdString_Q(...)
Usage
INP:LOW? (@103)
enter statement will return either FLO or 
WV for channel 3
INPut:POLarity
INPut:POLarity <mode>,<ch_list
sets logical input polarity on a digital 
SCP channel.
Parameters
Comments
If the channels specified are on an SCP that doesn't support this function, an 
error will be generated. See the SCP's User's Manual to determine its capabilities.
Related Commands: for output sense; SOURce:PULSe:POLarity
*RST Condition: INP:POL NORM for all digital SCP channels.
Send with VXIplug&play Function: hpe1422_cmd(...)
Usage
INP:POL INV,(@140:143)
invert first 4 channels on SCP at SCP 
position 5. Channels 40 through 43 
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
channel
channel list (string)
100 - 163
none
Parameter
Name
Parameter
Type
Range of
Values
Default 
Units
mode
discrete (string)
NORMal | INVerted
none
ch_list
string
100 - 163
none