76 Programming the VT1422A & VT1529A/B for Remote Strain Measurement  
Remote Strain Channel Addressing
Figure 3-15 shows the relationship between SCP positions and Remote 
Channel Addressing through the VT1539A SCP (see Figure 2-1 on page 36 
to compare with On-Board Channel Addressing). Not all SCP positions need 
to contain VT1539As. If needed, VT1539As can be mixed with other analog 
sense, source, and digital I/O SCPs.
Channels measured through Remote Signal Conditioning Units like the 
VT1529A/B Remote Strain Conditioning Unit are addressed with five digit 
channels specifiers rather than the traditional on-board channel’s three digit 
specifier. Both three and five digit specifier start with a "1." This is the SCPI 
"card number" digit and is retained in the VT1422A for SCPI compatibility. 
The next two digits complete the specification of an on-board channel. 
When used in a five digit remote multiplexed channel specifier, the first 
three digits mean the same as in the on-board specifier. Digits two and three 
specify the VT1539A SCP sense channel that is connected to a particular 
Remote Strain Conditioning Unit. Only the first two on-board channels are 
ever specified with the VT1539A Remote Channel SCP. So, digits two and 
three will specify channels 00, 01, 08, 09, 16, 17, 24, 25, 32, 33, 40, 41, 48, 
49, 56, or 57. This allows the VT1422A to address up to sixteen 
VT1529A/Bs. Digits four and five specify one of 32 channels on the RSCU 
and can range from 00 to 31.
Example channel addresses (shown in SCPI channel list syntax), see 
Figure 3-15 also:
Ch 0 on VT1529A/B connected to on-board chan 0 (VT1539A in SCP position 0).
(@10000)
Ch 0 on VT1529A/B connected to on-board chan 1 (VT1539A in SCP position 0).
(@10100)
Ch 24 on VT1529A/B connected to on-board chan 48 (VT1539A in SCP position 6).
(@14824)
Of course, in the Scan List, the channel list syntax allows a range of channels 
to be specified. Here are some examples:
channels 0 to 31 on each of the two VT1529A/Bs connected to on-board 
channels 0 and 1 (VT1539A in SCP position 0). This is 64 Chs.
(@10000:10131)
channels 0 to 15 on the VT1529A/B connected to on-board channel 24 
(VT1539A in SCP position 3).
(@12400:12415)
combined previous two examples into a single scan list to show combining 
ranges.
(@10000:10131,12400:12415)
Runtime Remote
Scan Verification
The VT1422A provides a method to verify that remote channels in the scan 
list defined in algorithms or with the ROUTe:SEQuence DEFine command 
are successfully scanned in each RSCU. See “Runtime Remote 
Scan Verification” on page 98
, “The Operating Sequence” on page 133 and 
“Runtime Remote Scan Verification” on page 187.