United States Stove 5660 사용자 설명서

다운로드
페이지 36
11
CLEARANCES TO COMBUSTIBLES
INSTALL ALL VENTS AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER!
When your Pellet Stove Room Heater is being installed on a combustible fl oor it is mandatory that a 1/2” (13mm) thick non-
combustible hearth pad be installed under the heater. The non-combustible hearth pad must extend at least 6” beyond the 
fuel loading and ash removal openings and at least the depth of the heater plus 6 inches (152mm) out in front of the heater.  
This applies to both freestanding heaters and insert heaters.
BACK WALL
Figure 5
Figure 6
Alcove Dimensions
36”
35”
40”
2”
6”
USA 6”
CANADA 8”
FLOOR PROTECTION
USA 6”
CANADA 18”
2”
FLOOR 
PROTECTION
USA 6”
CANADA 8”
USA 6”
CANADA 18”