TROUBLESHOOTING GUIDE
22
STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED
Possible Causes:
Possible Remedies:
1.    Fuse on control board blew.
Remove the control board. On the back, there is one fuse. If 
it appears to be bad, replace it with a 5 Amp 125 Volt fuse. 
Plug the stove back in and try to run the unit.
2.    High limit switch has tripped or is defective.
Wait for the stove to cool for about 30-45 minutes. It should 
now  function  normally.  If  not,  use  the  owner’s  manual  to 
locate the high limit thermodisc. To test if the thermodisc is 
bad, you can bypass it as described previously for the POF 
thermodisc.
3.    Bad auger motor.
Remove the auger motor from the auger shaft and try to run 
the unit. If the motor will turn, the shaft is jammed on some-
thing. If the motor will not turn, the motor is bad.
4.    Auger jam
Start by emptying the hopper. Then remove the auger motor 
by removing the auger pin. Remove the auger shaft inspec-
tion plate in the hopper so that you see the auger shaft. 
Gently lift the auger shaft straight up so that the end of the 
auger shaft comes up out of the bottom auger bushing. 
Next, remove the two nuts that hold the top auger biscuit in. 
Then rotate the bottom end of the auger shaft up towards 
you until you can lift the shaft out of the stove. After you 
have  removed  the  shaft,  inspect  it  for  bent  flights,  burrs, 
or broken welds. Remove any foreign material that might 
have caused the jam. Also, check the auger tube for signs 
of damage such as burrs, rough spots, or grooves cut into 
the metal that could have caused a jam.
4.    Loose wire or connector
Check all wires and connectors that connect to the auger 
motor, high limit switch, and the Molex connector. 
5.    Bad control board
If the fuse is good, the wires and connectors check out 
good,  and  the  high  limit  switch  did  not  trip,  test  fir  power 
going to the auger motor. If there is not a full current going 
to the auger motor when the fuel feed light is on, you have 
a bad control board.