13
PANEL CONTROLS
The blowers and automatic fuel supply are controlled from a panel on the left side of 
the appliance. The control panel functions are as follows:
A. ON/OFF SWITCH
• 
When pushed the stove will automatically ignite. No other fi restarter is necessary. 
The igniter will stay on for at least 10 and up to 15 minutes, depending on when 
Proof of Fire is reached. The fi re should start in about 5 minutes.
• 
The green light located above the On/Off button (in the On/Off box) will fl ash during 
the ignition start-up period.
• 
The Heat Level Advance is inoperable during the ignition start period. When the 
green light continuously stays on, the Heat Level Advance can be adjusted to 
achieve the desired heat output.
To manually ignite in case of ignitor failure. Place a handful of pellets in the burnpot. 
Add starter gel for pellet stoves, ignite, close door, turn the unit on.. Replace the 
ignitor as soon as possible.
NOTE:  If the stove has been shut off, and you want to re-start it while it is still warm, 
the “on/off” button must be held down for 2 seconds.
B. FUEL FEED SWITCH
• 
When the “Fuel Feed” button is pushed and held down, the stove will feed pellets 
continuously into the burn pot.
•  While the stove’s auger system is feeding pellets, the green light (in the “Fuel 
Control Panel
Feed” box) will be on.
CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE IT COULD SMOTHER THE 
FIRE AND LEAD TO A  DANGEROUS SITUATION.
C. HIGH FAN SWITCH
•  The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch overrides this variable speed 
function. It will set the room air blower speed to high at any feed rate setting.
• 
When the “HIGH FAN” button is pushed, the room air fan will switch to its highest setting.
• 
When this button is pushed again, the room air fan will return to its original setting based on the Heat Level Advance 
setting.
D. RESET TRIM
Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Heat Level Advance bar graph. 
This is usually a one-time adjustment based on the fuel you are using. The “RESET TRIM” button when adjusted 
will allow for 3 different feed rate settings for the #1 feed setting only. To adjust simply push the “RESET TRIM” button 
while the stove is operating at setting “1” and watch the bar graph.
• 
When the “1” & “3” lights are illuminated on the bar graph the low feed rate is at its “lowest” setting. (Approx. 0.9 
pounds per hour)
• 
When the “1” light is illuminated on the bar graph, the low feed rate is at its “normal” setting.
• 
When the “1” & “4” lights are illuminated on the bar graph, the low feed rate is at its “highest” setting.
NOTE: When the stove is set on “1” the “reset trim” values will be shown on the Heat Level Advance bar graph. For 
example if the Reset Trim is set to its lowest setting every time the stove is set to low the “1” and “3” lights will be 
illuminated on the bar graph.
E. HEAT LEVEL ADVANCE
• 
This button, when pushed, will set the pellet feed rate, hence the heat output of your stove. The levels of heat output 
will incrementally change on the bar graph starting from level “1” to “4”.
NOTE: When dropping 3 or more heat level settings (4 to 1,) push the ‘High Fan’ button and allow the room air fan to 
run at that setting for at least 5 minutes to prevent the stove from tripping the high temp thermodisc. If the high temp 
thermodisc does trip, see “SAFETY FEATURES”.