WARNINGS/SAFETY INFORMATION 
CONTINUED
17. CARBON MONOXIDE POISONING:  Early signs of carbon monoxide poisoning are
similar to the flu with headaches, dizziness and/or nausea.  If you have these signs,
obtain fresh air immediately.  Have the heater serviced as it may not be operating
properly.
18. This vent-free gas fireplace is intended to be smokeless.  If logs appear to smoke, turn off
the heater and call a qualified service person.  Initial burn off may cause slight smoke and
odor during the first four hours of operation.
19. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet.  For
elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000
feet above see level.  Refer to the National Fuel Gas Code.
20. The fireplace and its individual shut off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of
1/2 psig (3.5 kPa).
21. The fireplace must be isolated from the gas supply piping system be closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
22. Do not use this gas fireplace if any part has been under water.  Immediately call a
qualified service technician to inspect the room heater and to replace any part of the
control system and any gas control which has been under water.
VFZC32 SPECIFICATIONS
Natural Gas
Manifold Pressure Setting:
4" w.c.
Gas Inlet Pressure:
Maximum
10-1/2" w.c.
Minimum
5" w.c.
Propane/LPG
Manifold Pressure Setting:
10" w.c.
Gas Inlet Pressure:
Maximum
13" w.c.
Minimum
11" w.c.
Gas Rate
Number
Model Number
Type
Max BTU/Hr
Min BTU/Hr
of Burners
VFZC32N
Manual
30,000
8,000
2
VFZC32L
Manual
30,000
8,000
2
Controls
 - Main control has 4 positions:
1.
OFF - All gas to the gas logs is shut off at the control
2.
IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3.
PILOT - Valve position to light/maintain a standing pilot
4.
ON - Gas flow to complete system, front burner ignition
Front Burner Control Knob
 - infinite control, rotate clockwise to minimum rate and counterclockwise
to maximum rate.
Rear Burner Control Knob
 - Has 3 positions:
1.
OFF - Gas to rear burner is shutoff at control
2.
ON/MAX - Maximum gas flow to rear burner
3.
MIN - Minimum gas flow rate to rear burner