Error Messages
This chapter explains error messages that may be displayed on the Hand-held Monitor.
Powerup Error Messages
If an error occurs during the Hand-held Monitor’s
self-test, this multi-language error display may
appear:
self-test, this multi-language error display may
appear:
P W R U P E R R O R # 1
E R R E U R # 1
E I G T E S T : F E H L # 1
E R R O R E I N I Z # 1
Cycle power to the Hand-held Monitor and try
again. If the message returns, look for its error
number in the list at right.
again. If the message returns, look for its error
number in the list at right.
#2
The HHM has a faulty EPROM. Obtain a
replacement or an HHM upgrade kit.
replacement or an HHM upgrade kit.
#4
The HHM may have been assigned a De-
vice Number already used on the bus. Press
the ON/OFF key, then disconnect the HHM
from the device it is attached to. Press the
ON/OFF key again. Following the instruc-
tions on page 3-4, assign the HHM a differ-
ent Device Number.
At 38.4 Kbaud, unterminated HHM cable
may cause this message. Remove the HHM
cable or check that HHM is connected to a
properly-terminated bus.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.
vice Number already used on the bus. Press
the ON/OFF key, then disconnect the HHM
from the device it is attached to. Press the
ON/OFF key again. Following the instruc-
tions on page 3-4, assign the HHM a differ-
ent Device Number.
At 38.4 Kbaud, unterminated HHM cable
may cause this message. Remove the HHM
cable or check that HHM is connected to a
properly-terminated bus.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.
#5
This number indicates an internal fault, or
excessive noise on the bus, or that the bus is
operating at a different baud rate from the
HHM. Press the ON/OFF key then discon-
nect the HHM cable from the bus
excessive noise on the bus, or that the bus is
operating at a different baud rate from the
HHM. Press the ON/OFF key then discon-
nect the HHM cable from the bus
and from
the HHM. Press the ON/OFF key again. If
the message reappears, replace the HHM.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.
the message reappears, replace the HHM.
This error may occur if the Hand-held Mon-
itor is connected to a bus and an incorrect
baud rate is selected.
#1, 2, 3,