Automation and Drives - SCE 
 
 
 
 
 
T I A  Training Document 
Page 103 of 129 
  Module 
 
 
 
         F6 
Issued: 02/2008 
Operator Control with WinCC flexible 2005 
Preface Installation Project Description Step7 Project HMI Station WinCC flexible Project Messages Recipes User Management 
8.3.7 
Configuring the Mixer Motion 
 
We are using a graphic EA field for animating the mixer motion. By means of a graphic list, the mixer 
motion is shown as in an animated cartoon.   
 
Create a new graphic list with the name “Mixer Motion“. 
At Value (Wert) 0 to 12, insert from the template directory the graphics “Mixer1“ to “Mixer7“ first in an 
ascending sequence and then in a descending sequence.