Siemens Webcam TP177B 사용자 설명서
Automation and Drives - SCE
T I A Training Document
Page 95 of 129
Module
F6
Issued: 02/2008
Operator Control with WinCC flexible 2005
Preface Installation Project Description Step7 Project HMI Station WinCC flexible Project Messages Recipes User Management
8.3.3
Configuring the Manual Mode for the Outflow Valve of the Container
We are creating an additional button for opening the outflow valve.
From the tool window, under Basic Objects, drag a Button into the basic display.
Under Allgemein (General), at Text AUS, enter “Ablauf öffnen“ (open outflow). Set the check mark
for Text EIN, and enter the text “Ablauf offen“ (outflow open).
Caution! After entering the text, don’t press the enter key; otherwise, a new line is generated.
Change the background color to white, and select a smaller font size.
Set the position and the size.
We are creating an additional button for opening the outflow valve.
From the tool window, under Basic Objects, drag a Button into the basic display.
Under Allgemein (General), at Text AUS, enter “Ablauf öffnen“ (open outflow). Set the check mark
for Text EIN, and enter the text “Ablauf offen“ (outflow open).
Caution! After entering the text, don’t press the enter key; otherwise, a new line is generated.
Change the background color to white, and select a smaller font size.
Set the position and the size.
In the function list, select the function “SetzeBit“ at Drücken (press).
From DB1, select as variable “hand_ablauf_behaelter“ (manual outflow container).
We want to generate the function of a button; for that reason, we are now configuring the function
“RuecksetzeBit“ (reset bit) with the variable “hand_ablauf_behaelter“ when releasing the button.