TC12 Installation, Commissioning & Maintenance Handbook 
4.4 
OVERVIEW OF TEST SET SOFTWARE SETTINGS/SELECTIONS AND 
OPERATION 
4.4.1  Modes of Operation 
4.4.1.1 Monitor Mode 
Monitor mode allows control and reply messages to be monitored at either the 
Instation or at an OTU. 
 
When the ITS is operating in this mode, the operation of any key (except the mode 
selection key) has no effect on the data being transmitted between the Instation 
and the OTU. 
 
Connecting the ITS (in this mode) to the OTU or ITU does not cause an error in 
the data being transmitted between the Instation and the OTU for more than one 
second. 
 
4.4.1.2 Instation Mode 
In this mode the ITS replaces the computer and the Instation equipment. The ITS 
transmits at one second intervals to a selected OTU, a control message in 
accordance with the control data setup and displayed on the PC 
 
4.4.1.3 Outstation Mode 
In this mode the ITS replaces a selected OTU. The ITS displays any two 
characters of the control message being transmitted by the computer. In response 
to the control message the ITS transmits a reply message containing the data 
setup on the display. 
 
4.4.2  Screens / Functions of the ITS 
4.4.2.1 Manager 
Under this menu option, the user can choose to recall or save the data entered for 
the current line configuration i.e. number of OTUs on the line, number of control 
and reply bytes for each OTU, optional OTU identifier strings for each OTU, baud 
rate, 2 or 4 wire and full or half duplex. 
 
4.4.2.2 System Setup 
Under this menu option the user can select screens to enter various items of data 
concerning the system and test set up. 
 
4.4.2.2.1 ITS Modes 
This allows the setting up of the mode of operation for the ITS. 
666/HE/43100/000  
Page 143 
Issue 9