Siemens Network Hardware SM2 monitoring system 사용자 설명서
66
U3585-J-Z125-8-76
ADD-BCAM-CONNECTION-SET
Statements for SM2 administrators
ADD-BCAM-CONNECTION-SET
Add connection set for BCAM-CONNECTION monitoring
Add connection set for BCAM-CONNECTION monitoring
Function
This statement is used to define a connection set which is to be added to the BCAM-
CONNECTION monitoring program definition.
CONNECTION monitoring program definition.
The following features must be specified:
–
–
the type of connection with local and partner (connection) names
–
the names of the local and partner systems
–
an indication of whether the connections are local or remote
It is possible to define up to 32 connection sets.
This statement must be preceded by a SET-BCAM-CONNECTION-PARAMETER
statement.
statement.
Format
ADD-BCAM-CONNECTION-SET
,CONNECTION-SELECTION = *BY-NEA-NAME(...) / *BY-PORT-NUMBER(...)
*BY-NEA-NAME(...)
*SPECIFIED(...)
*BY-PORT-NUMBER(...)
*SPECIFIED(...)
,CONNECTION-TYPE = *REMOTE / *LOCAL / *BOTH
*SPECIFIED(...)