Sea Frost DC 5000 사용자 설명서

다운로드
페이지 46
 
25
GAUGES 
 
Gauges must be used in the evacuation and charging.  They will provide information on 
the operation of the system when troubleshooting. 
 
A gauge sets consist of two gauges installed in a manifold with two hand wheel valves 
and hoses to connect the gauges to the system.  The left gauge (blue) is a compound 
device; it indicates pressure and also vacuum.  The right gauge (red) indicates pressure 
only.  The hand wheels open a center port (yellow) to the left or right side respectively.  
Operation of the hand wheels is only necessary when moving refrigerant or evacuating.  
With the hand wheels closed, the gauges read the pressures of the connection points.  
At the end of the red and blue service hoses are R-134a connecting valves.  At the end 
of the yellow hose is a self-sealing check valve that will only open when attached to a 
fitting. 
 
 
 
Keep your gauges clean.  Inspect the rubber gaskets and "o" rings on the hose ends. 
Leak-check the gauge valve packing and all hose connections.  Check and reset the 
"O" (zero) on the low side gauge while open to atmospheric pressure, if necessary. 
 
 
R-134a SERVICE CONNECTING VALVES 
 
The R-134a connecting valves on the gauge hose ends are quick connect fittings with a 
specially designed valve that when turned opens and closes the hose end while 
opening and closing the access service port.