The following tables define the available factory modifications for the Class 8839 58M Enclosed AC Drives. These factory 
modifications offer maximum flexibility for many complex job specifications. All modifications follow specific interoperability rules for 
selection. Modification selection can be validated at time of quotation or order entry by the Square D Quote to Cash Product 
Selector.
 Control Options
Code AFC Controls
A07
 
Hand/Off/Auto, Speed Potentiometer
B07
Hand/Off/Auto, Start/Stop, Speed Potentiometer
C07 
Start/Stop, Speed Potentiometer
D07
Stop/Start, Forward/Reverse, Speed Potentiometer
E07
Hand/Off/Auto, Local/Remote, Speed Potentiometer
F07
Communication/Auto/Off/Hand, Speed Potentiometer
 Light Options
Code Light cluster
A08 
Red Power On
Green AFC Run
Yellow AFC Fault
Yellow Auto
B08 
Red Power On
Green AFC Run
Yellow AFC Fault
Yellow Bypass
C08 
Red Power On
Green AFC Run
Yellow AFC Fault
D08
Red Power On
Yellow AFC Fault
Green Run Forward
Green Run Reverse
E08
Red Power On
Green AFC Run
Yellow AFC Fault
Blue Hand
Yellow Auto
F08
Red Power On
Green AFC Run
Yellow AFC Fault
Yellow Communication
 Option Cards
Code Feature
A09 
MODBUS
®
 Plus
B09 
MODBUS / UNITELWAY
C09 
METASYS N2
D09 
Ethernet
E09 
L
ON
W
ORKS
 Gateway
F09 
DEVICENET
H09 
Analog card adds 1 additional analog output, 
2 additional logic inputs, 1 additional logic output, 
and 1 differential analog input.
 Miscellaneous Options
Code Feature
A10 
Line Reactor nominal 5% impedance
B10 
Line Contactor
C10
3–15 psi Transducer
D10 
Omit Keypad
E10 
Smoke Purge Relay
F10
(Reserved)
G10
cUL Listing
H10 
Seismic Certification (Floor-mounted Enclosures)
J10 
0–10 Vdc Auto Speed Reference
K10
Additional N.O. Auxiliary Drive Run Contact
L10
Additional N.C. Auxiliary Drive Fault Contact
M10
1 N.O. Auxiliary Bypass Run Contact
N10 
(Reserved)
O10 
1 N.O. Auxiliary Auto Mode Contact
P10
AFC Fault Reset
Q10
 
Push-To-Test Pilot Lights
R10
Auto Transfer to Bypass
S10
Motor Elapsed Time Meter
T10
Emergency Stop
U10
Motor Space Heater Sequencing
V10
Seal Water Solenoid
W10
Check Valve Sequencing
X10
(Reserved)
Y10
(Reserved)
Z10 
24 Vdc Power Supply
110
Additional Control Power VA
210
(Reserved)
310
Order Engineered Special (internal use only)
410
RFI Suppressor
510
Permanent Wire Marker Sleeves
610
I.D. Engraved Nameplates
710
Harmonic Filter Provisions
810
(Reserved)
910
Barriered Bypass Enclosure 
 Miscellaneous Options