Russound CA4 System Installation  Manual
INSTALLATION OVERVIEW
Ventilation Requirements
IMPORTANT: The CA4 should be situated so that its location or position does 
not interfere with its proper ventilation. Do not block vents above or to the 
sides of the unit, as it requires ventilation for proper operation. Do not expose 
to excessive dust, and do not allow dust to build up on the unit and block vent 
holes.  Do  not  place  the  CA4  above  or  below  a  heat-generating  component 
such as an audio amplifier.  
Be sure to leave at least 2 inches of space to the sides of the unit with open air 
flow above. A single-space rack mount vent or about 1.75 inches must be kept 
clear above and below the unit.
Installation
The CA4 controller can be rack mounted or placed on a shelf in an equipment 
rack. The controller will occupy one rack space with the feet removed. 
The controller can be installed in an equipment rack using the included rack-
mount ears and hardware to attach the ears to the controller chassis. 
Two controllers may be connected and allow up to 8 keypads on the system. 
Electrical Power
The  CA4  operates  at  100  to  240 VAC. Voltage  is  auto  selected  internally.  It 
is recommended that the CA4 and the source equipment be plugged into a 
dedicated  20-amp  circuit  with  an  isolated  ground.  A  power  line  conditioner 
can  reduce  interference  problems  caused  by  noise  found  in  some  electrical 
systems. 
Warning: There is no external on/off power switch on the CA4. If the controller 
is plugged in to a live AC outlet, it will be powered. To cycle power, you must 
unplug the controller and then plug it back in. 
Important Considerations
Disconnect  the  power  cord  before  making  any  connections  to  the 
controller.
Verify that all connections and polarity are correct.
Keep all power cords away from all signal cables to prevent humming from 
induced noise.
Choose reliable signal cables and patch cords.
Label all wires with the room location at both ends of the wire.
Avoid  running  speaker  wires  or  signal  cables  close  to  house  electrical 
wiring for any distance. If you have to run them parallel, make sure to space 
the wires at least two feet from the AC line. If you need to cross an AC line it 
should be at a 90° angle.
For dual controllers, use a keypad connected through a wall port to set the 
ID on the second controller before linking the controllers. 
Do  not  connect  the  controller’s  main  power  feed  until  all  other 
connections  have  been  made  and  verified.  Live  connection  or 
removal  of  the  keypad  wiring  or  other  wiring  when  the  system 
is  powered  can  cause  communication  problems  in  the  network. 
Double-check  terminations  during  each  phase  of  the  installation 
to prevent accidental damage. Incorrect wiring is the number one 
cause for non-warranty product damage.