10.3. Periodical maintenance
Operation to be carried out with 
the machine under pressure.
 Discharge the water from the boiler with hot water 
delivery switch 5
 Wait until the machine has returned to heat equi-
librium before reuse.
10.2. Weekly
Operations to be carried out with the machine 
operative and under pressure.
 Place  the  supplied  blind  filter  in  the  filter-holder, 
put in a spoonful of detergent in powder for coffee 
machines and fit the filter-holder in the unit to be 
cleaned.
 Press the coffee dispensing button and draw water 
for approx. 30 seconds.
 Stop and start dispensing several times until clean 
water comes out of the discharge unit tube.
 Remove the filter-holder, take out the blind filter and 
insert a normal one.Replace the filter-holder on the 
unit and rinse by drawing water several times.
● 
Make a coffee to eliminate any unpleasant taste.
Cleaning the filters and delivery heads 
Operation to be carried out when the machine is off 
and cold.
 Prepare a solution of 4 sachets of detergent powder 
Code 69000124 dissolved in a litre of boiling water 
in a stainless steel, plastic or glass recipient (NOT 
ALUMINIUM OR IRON
).
 Remove the filters and immerse them with the filter 
holders in the prepared solution, leaving them for 
at least 10/20 minutes (all night is better).
 Remove them from the container and rinse them 
thoroughly in running water.
Tank cleaning (Fig.10 - 11)
 Remove  the  cup-stand  grille  1  (Fig.10)  and 
clean.
 Check  and  clean  the  drainage  sump  3  (Fig.11), 
removing any sludge with the help of a spoon.
10.3.1. Renewal of water in the boiler
(Fig.12)
To be carried out only by qualified person-
nel.
 Turn off the machine and wait for the pressure in 
the boiler to diminish (gauge needl on “0”).
 Insert a rubber hose (1) into the hose-end fitting 
(2) 
 Loosen the hose-end fitting (2).
 Allow the water to flow out completely; then, close 
the fitting (2) and remove the rubber hose (1).
 Refill the boiler (paragraph 7.3.).
10.3.2. Regeneration
Softener DP2 - DP4
Regenerate the water softener within the time-limi-
ts specified for the softener as follows:
DP2
nr.1 regeneration per month for 500 coffees/day;
nr.2 regenerations per month (once a fortnight) for 
1000 coffees/day.
DP4
nr.1 regeneration per month for 1000 coffees/day;
nr.2 regenerations per month (once a fortnight) for  
 2000 coffees/day.
This table has been drawn up according to a water har-
dness of 25 degress calculated on the French scale.
See the documentation included with the softener 
for the instructions for use.
Model S1 TANK (Fig.13)
Operation to be carried out when the machi-
ne is off and cold and with the plug discon-
nected.
To  be  effected  after  the  consumption  of  approx.15 
litres  of  water  (average  hardness  calculated  as  35 
degress  on  the  French  scale)  or  at  least  once  a 
month.
 Prepare a solution in a glass of water adding three 
teaspoons of fine salt (the salt must be properly 
dissolved).
 Drain the water-tank, see point 10.2.
 Slide the softener 1 (Fig.13) off the rubber tubing 
2 and turn it over.