CDM-600 Satellite Modem 
Revision 7 
Automatic Uplink Power Control (AUPC)  
MN/CDM600.IOM 
12–4 
12.4 Monitoring 
 
The remote demodulator’s value of Eb/No can be monitored at all times, either from the 
front panel (MONITOR, AUPC) or via the remote control interface. The resolution of 
the reading is 0.2 dB. For all values greater than or equal to 16 dB, the value 16.0 dB will 
be displayed. As long as framing is enabled, the value will still be available, even though 
AUPC may be disabled. 
 
Also displayed is the current value of TX power increase. If EDMAC framing is enabled, 
but AUPC is disabled, this will indicate 0.0 dB. This value is also available via the 
remote control interface. 
 
 
CAUTION
 
Comtech EF Data strongly cautions against the use of large values of 
permitted power level increase under AUPC control. Users should 
consider using the absolute minimum range necessary to improve rain-