Pitco Frialator L20-316 사용자 설명서

다운로드
페이지 12
 Solstice I12 Water Cooker Computer Service
Part #60153301
L20-316 Rev 0
10
3.4 
Language Selection:
With display showing [PROGRAM], press the location key 
.
Display shows [SELECT] [OPTIONS].
Press product key 4, display shows [ENGLISH] [LANGUAGE].
Use the location key 
 to scroll through choices (ENGLISH, ESPANOL, FRANCAIS,
DEUTSCH, HOLLAND).
Press 
 key to save choice.  Display shows [PROGRAM].
3.5 
Recovery Test Value:
This controller maintains a record of heat up times for the appliance.  A poorly running appliance will
have increased recovery times stored in this display.  There is no selection done here, just the display
of recovery time values.
With display showing [PROGRAM], press the product key 
.
Display shows [SELECT] [OPTIONS].
Press product key 6; display will show [RECOVERY] [TEST].
Press the product key 
.  Display will show [FnnnLyyy], where nnn is the factory
recovery value, and yyy is the last warm up recovery value.
After recording these values, press the 
 key.  Display returns to [PROGRAM].
3.6 
Control or Timer:
With display showing [PROGRAM], press the product key 
.  Display shows [SELECT]
[OPTIONS].
Press product key 7; display will show [CONTROL].
Use the product key 
 to scroll through choices (Control, Timer).
Press 
 key to save choice.  Display shows [PROGRAM].
Note: If timer is selected, heat control outputs are disabled, leaving only the timer functions active.  For
normal appliance operation, this setting should be left on the “Control” setting.