Program 
Interaction 
After the connection is established, mapping has been set up, and polling enabled, the 6K starts 
exchanging data automatically with the PLC. Here is how to: 
•  Write a binary variable to the PLC: Write a value to one of the 
VARB
 variables in the 
NTMPWB
 mapping. The new data is written to the binary file during the next poll. 
•  Write an integer variable to the PLC: Write a value to one of the 
VARI
 variables in the 
NTMPWI
 mapping. The new data is written to the integer file during the next poll. 
•  Read a binary variable from the PLC: The 
VARB
 variables in the 
NTMPRB
 mapping 
correspond to the values in the binary file in the PLC.  
•  Read an integer variable from the PLC: The 
VARI
 variables in the 
NTMPRI
 mapping 
correspond to the values in the integer file in the PLC. 
Example 
VARB100 = HAB79  ; Element 3 in file 10 of the AB PLC will be equal to VARB100 
if(VARB106 = B1111111111111111)    ; VARB106 will be equal to variable 7 in  
                                   ; file 10 of the AB PLC  
if(VARI129 = 17)  ; Element 6 in file 20 of the AB PLC will be equal to VARI129 
VARI121 = 17 
; Element 4 in file 20 of the AB PLC will be equal to VARI121 
 
 
page 14