\TANI 
Transfer Network Analog Input Status
 
Type: 
Network; Transfer 
Product Rev 
Syntax: 
<!>n\mTANI<.i> 
Units: 
n = network server # 
m = module # 
i = analog input # on module “m” (for bit-select operation) 
(The response represents volts DC.) 
Range: 
n = 1-6 
m = 0-7 
i = 1-2 
Default: 
n/a 
Response: 
1\1TANI: 
1\1TANI.2: 
*2.42,3.32 
*3.32 
See Also: 
[ \ANI ], NTIO, \TIO 
6K 5.3 
    
The 
\TANI
 command returns the voltage present at one of the network analog inputs. The network server number and 
module number must precede the 
\TANI
 command (e.g., 
2\3ANI
 reports the voltage present on all analog inputs on 
module 3 of network server 2). 
If the status of a specific analog input is required, use the bit select operator (.). For example, 
1\3TANI.2
 reports the 
voltage of analog input 2 on module 3 of network server 1. 
The controller addresses the OPTO22 I/O locations as follows: 
Each I/O bit is addressed by its location on a specific module. (NOTE: I/O points are not addressed by an absolute 
32-bit location on the OPTO22.) Digital input and output modules have four I/O points, or channels, and are numbered 
1-4. Analog input and output modules have two I/O points, or channels, and are numbered 1-2. 
Digital
Input
Module
Input
1
0
Input
2
Input
3
Input
4
Digital
Input
Module
Input
1
1
Input
2
Input
3
Input
4
Digital
Output
Module
Output
1
2
Output
2
Output
3
Output
4
Digital
Output
Module
Output
1
3
Output
2
Output
3
Output
4
Analog
Output
Module
Output
1
4
Output
2
Analog
Output
Module
Output
1
5
Output
2
Analog
Input
Module
Input
1
6
Input
2
Analog
Input
Module
Input
1
7
Input
2
EXAMPLE: OPTO22 is Network Server #2
2\0TIN.3
2\3TOUT.2
2\5TANO.1
2\7TANI.2
 
page 40