The ECXTRA features built-in circuit protection to help 
prevent damage to the timer caused by excessive current 
draw on the zone and/or pump/master valve circuits. 
The instant an overload condition 
is detected, the affected zone is 
turned OFF and the next zone in 
the watering sequence is turned 
ON. The word “Fuse” and the bypassed zone number(s) 
will begin flashing. 
If the condition occurs on the 
pump/master valve circuit, the 
timer will alternately display MV 
and FUSE and discontinue the 
program operation.
To clear the warning display, 
 press the 
–/
off
 button. 
The timer will resume normal operation as scheduled and 
will attempt to run all zones as programmed. 
IMPORTANT: Clearing the display does not correct 
the problem. The timer will continue to bypass the 
affected zones or discontinue operation until the 
overload condition is eliminated. Generally this con-
dition is caused by a faulty valve solenoid or pump 
start relay. Before continuing to operate the timer, 
take corrective action to resolve the cause of the 
problem.
1.  Turn the control dial to the 
off
position.
2.  Remove the lower front cover from the timer housing 
by sliding it downward.
3.  Place the back of the zone control module (model # 
53741) squarely between the guides of the first open 
expansion slot (from left to right). Pushing lightly on 
the bottom of the module, slide it upward until it locks 
into position.
4.  To connect the valve wires, refer to “Connecting the 
Valves” on page 7 or 11.
5.  Install the lower front cover. 
6.  To set the zone run time, refer to “Setting Zone Run 
Times” on page 28.
7.  To test the operation of the new watering zone(s), 
refer to “Manual Operation” on page 31.
Automatic Circuit Protection
Adding a Zone Module

SENSOR
SENSOR
24VAC
 FUSE
ALK
NiCad
DELAY
24HR
12HR
9V Battery
ON
OFF
8