4.3.2 Gap/Black Mark Calibration, Self-test and Dump Mode 
 
While calibrate the gap/black mark sensor, printer will measure the label length, print 
the internal configuration (self-test) on label and then enter the dump mode. 
To calibrate 
gap or black mark sensor, depends on the sensor setting in the last print job. 
Please follow the steps below to calibrate the sensor. 
1.Turn off the power switch. 
2. Hold on the button then turn on the power switch. 
3. Release the button when LED becomes amber and blinking. (Any amber will do 
during the 5 blinks) 
 
  The LED color will be changed as following order. 
Amber  red (5 blinks)  amber (5 blinks)  green (5 blinks)  green/amber (5 
blinks)  red/amber (5 blinks)  solid green 
 
4. It calibrates the sensor and measures the label length and prints internal settings 
then enter the dump mode. 
 
Note: 
Please select gap or black mark sensor by Diagnostic Tool or by GAP or BLINE command prior to 
calibrate the sensor. 
For more information about GAP and BLINE command, please refer to TSPL2 programming 
manual.