User’s Guide and Reference
4 - 7
Basic Modem Operation
Short
Long
Description
Form
Form
62
CONNECT  24000
connection at 24000 bps  *
63
CONNECT  26400
connection at 26400 bps  *
64
CONNECT  28800
connection at 28800 bps  *
66
COMPRESSION  CLASS 5 MNP  data  compression
67
COMPRESSION  V.42BIS
V.42bis  data  compression
69
COMPRESSION  NONE
no  compression
76
PROTOCOL  NONE
connection with Modem that does
not support MNP or V.42
77
PROTOCOL:  LAP-M
connection with Modem that
supports V.42
80
PROTOCOL:  ALT
connection with Modem that
supports MNP
81
PROTOCOL:  ALT - CELLULAR
connection with Modem that
supports MNP-10
*Only applicable to Trumpcard 28800 version
Ending Your Connection
To end your connection, log off the remote system (if applicable), enter the
escape sequence (+++), and issue the ATH command.
You may want to wait 30 seconds or so after your last transmission before
disconnecting to ensure any data in the Modem buffer has cleared.
Setting Up for a Non-Error Correcting
Connection
The Trumpcard Modem supports the  V.42 and MNP error correction
protocol as its default mode. When you initiate a connection from your
Trumpcard 
 Modem to a remote Modem not supporting error correction,
the remote system may respond with garbled characters or even lock up.
If the remote Modem does not support error correction, the Trumpcard
continues the connection without error correction or data compression.
However, as mentioned, the remote system may have already locked up.
In these cases, you must break the connection, turn off error correction on
the Trumpcard, and place your call again.
To turn off error correction for the Trumpcard,
 use the AT&Q6 command. If
you wish to make this (non-error correcting) the default setting, follow the