SHUTDOWN PROCEDURE 
 
Turning your OSBURN stove off is a matter of pressing 
 on the control panel.  The blowers will continue to operate until internal firebox 
temperatures have fallen to a preset level.  The stove cannot restart before it has completely shut down. 
 
SAFETY FEATURES 
 
a. 
Your stove is equipped with a manual reset high temperature switch (also called heat sensor or heat switch). The switch has a reset button on 
its backside.  Like a circuit breaker, once tripped, the reset button will have to be pushed before you can restart the stove. The high 
temperature switch protects the stove against overheating due to of an evacuation problem, a control board problem, a blower problem, or any 
other problem causing the unit to overheat.  The manufacturer recommends that you contact your dealer if this occurs as it may hide a major 
problem. A service call may be required.  
 
NOTE:  If an overheating situation occurs, the high temperature switch (called the L-250 manual reset) will automatically shut down the auger 
motor (fuel feed system) and an error code 
 will appear. 
 
b. 
If the combustion blower fails, an air pressure switch will automatically shut down the auger and an error message 
 will appear. This safety 
feature is to prevent the unit from igniting or burning fuel when the combustion/exhaust blower has failed, therefore preventing combustion 
fumes from spilling into the room.   
 
c. 
If the temperature in the auger rises beyond a certain acceptable level, two high temperature switches located under and above auger housing 
will stop the fuel feed system and an error 
 will appear.   
 
CODE BEFORE 
RESETING 
TO 
RESET 
H1, H2, H3  
OR H4 
Heat exchanger and/or exhaust system  
is/are clogged.  Refer to the owner’s manual 
for maintenance procedures. 
Press simultaneously for 2 seconds 
 
and 
 icons. 
*** After 3 attempts, reset is no longer possible, call SBI technical support. 
 
DAMPER OPERATION 
 
OP
EN
CL
OS
E
OP
EN
CL
OS
E
INSERT
STOVE
 
Figure 40 
Damper operation 
Stove & Insert
 