Osburn Stoves by SB I HYBRID 35 사용자 설명서

다운로드
페이지 34
STOVE STOPS FEEDING  PELLETS AND SHOWS 
ERROR CODE “H” 
 
 
Possible Causes:
Possible Remedies:
 
1.      One of the two L-250 automatic high temperature switch has   
tripped. 
 
The L-250 automatic high temperature switch is located on the 
auger housing top and bottom  It will send a signal to the control 
board if the auger housing overheats.   Wait until the stove cools 
down. YOU NEED TO INSPECT YOUR UNIT AT THIS POINT.   
There might be a problem with another component or the 
installation, causing the stove to overheat.  Reset the stove and 
restart it. Call a technician if you get this code again. 
 
*See procedure below to restart the stove. 
 
CODE 
BEFORE RESETING 
TO RESET 
H1, H2, H3  
OR H4 
Heat exchanger and/or exhaust system  
is/are clogged.  Refer to the owner’s manual 
for maintenance procedures. 
Press simultaneously for 2 seconds 
 
and 
 
icons . 
*** After 3 attempts, reset is no longer possible.  Call SBI technical support. 
 
STOVE STOPS FEEDING  PELLETS AND SHOWS 
ERROR CODE “d” 
 
Possible Causes:
Possible Remedies:
 
1.      The hopper lid has stayed open for more than 3 minutes  
      
 
As a security measure, the auger will stop turning and feeding pellets as 
soon as the hopper lid opens. It will resume normal operation as soon as 
the hopper lid is closed.  However,  if the hopper lid stays open for more 
than 3 minutes, the unit will stop and a code “d” will appear on the control 
board.  Close the hopper lid.  Reset the unit and start it again. 
 
SMOKE SMELL COMING BACK INTO THE HOME 
Possible Causes:
Possible Remedies:
 
1.    There is a leak in the vent pipe system. 
 
Inspect all vent pipe connections.  Make sure they are sealed with RTV 
silicone that has a temperature rating on 500
o
F or higher.  Also, seal joints 
with UL-181-AP foil tape.   
 
 
2. 
The gasket on the combustion/exhaust blower housing has 
         gone   bad. 
 
Inspect the gasket on the combustion/exhaust blower housing to make 
sure it is in good shape and replace if necessary. 
 
 
 
AUGER MOTOR STOPS FEEDING PELLETS AND COMES BACK ON 
Possible Causes:
Possible Remedies:
 
1.  The auger motor is overheating 
and tripping the internal 
temperature shutoff (thermal 
protector). 
 
 
Start by emptying the hopper.  Follow procedure described in error code “E” section #6.   
 