Orbit Manufacturing ORBIT 2000 사용자 설명서
Page 4 - 9
Installation
Orbit™ 2000 Operation and Maintenance Manual
© GBC Films Group January 2001
4.7 Initial inspection
ELECTRICAL
S H O C K
Remove power to the laminator before performing step ( a ) below. Contact with
electrical components while power is supplied can result in injury or death!
a/
Electrical assembly inspection
– Component mounting
– Terminal security
– Wire tightness
– Circuit breaker wires
ELECTRICAL
S H O C K
Electrical troubleshooting should be left to qualified GBC service technicians!
Electrical shock hazard!
b/
Protective circuit inspection
– The safety of protective circuits may be checked by feeding a current of at least 10 A (50
Hz) from the PELV source for at least 10 seconds. The test is done between the PE terminal
and various points that are part of the protective circuit. See EN 60204-1, article 20.2.
Hz) from the PELV source for at least 10 seconds. The test is done between the PE terminal
and various points that are part of the protective circuit. See EN 60204-1, article 20.2.