 NT5D11 and NT5D14 Lineside T1 Interface cards
Man-Machine Interface
The lineside T1 card provides an optional Man-Machine Interface (MMI) that 
is primarily used for T1 link performance monitoring and problem diagnosis. 
The MMI provides alarm notification, T1 link performance reporting and 
fault isolation testing. The interface is accessed through connections from the 
I/O panel to a terminal or modem.
The MMI is an optional feature since all T1 configuration settings are 
performed through dip switch settings or preconfigured factory default 
settings.
Electrical specifications
T1 channel specifications
Table 77 provides specifications for the 24 T1channels. Each characteristic is 
configured by dip switches. 
Table 77
Lineside T1 card – line interface unit electrical characteristics
Characteristics
Description
Framing
ESF or D4
Coding
AMI or B8ZS
Signaling
Loop or ground start A/B robbed-bit
Distance to Customer Premise 
Equipment (CPE) or Channel 
Service Unit
0-199.6 meters (0–655 feet)