9.3  
LIST MENU
The List menu Table 7 provides the user dependent upon Access level with the following options. When the
event printer is installed within the control panel, the user will also have the option to view or print the requested
listing.
LIST – Menu Functions
Sub-Menu 1
Sub- Menu 2
Access
Level 2
Access
Level 3
Function
Zones
All Zones
"
"
View text message allocated to each fire zone.
Zone Information
"
"
View fire zone parameters (T1, T2, BGU override & double
knock) and devices assigned to the zone.
Loop devices
Single loop
"
"
View all devices connected to the specified loop. Provides
device type, text message & zone allocation.
Device range
"
"
View range of devices attached to specified loop. Provides
device type, text message & zone allocation.
Forward scan
-
"
Reverse scan
-
"
View devices in one direction only. Used to identify break or
open circuit on loop detection cable.
Analogue values
-
"
View additional analogue threshold values, current & fire
levels for each individual device attached to specified loop.
Single device value
-
"
View a specified device information including type, text
message & threshold values.
Loop current
-
"
Determine the amount of current used by the detection loop.
Loop integrity
-
"
View the number of scans against errors reported by the
detection loop since the last panel reset.
Output groups
All groups
"
"
View text message allocated to specified range of output
groups.
Group information
"
"
View output group parameters (T3, T4, Evacuate, silence &
activation control) and devices assigned to the group.
Panel functions
BLC outputs
"
"
View MBLC Sounder & Relay output location text
messages.
Motherboard
-
-
N\A
Plant
All plants
"
"
View text message assigned to the plant zones (when
installed).
Plant information
"
"
View devices assigned to plant zones (when installed).
Isolations
Zones
"
"
View complete isolated fire zones.
Loop devices
"
"
View single devices that are currently isolated.
Output groups
"
"
View isolated output groups.
Panel functions
"
"
View isolated MBLC sounder and or relay outputs.
Plant
"
"
View isolated plant zones.
Event log
All events
"
"
View all events occurring on the panel in date \ time order.
Range (date)
-
"
View events for the specified date.
Priority event
-
"
View events by priority (1 = Fire events)
Engineer info
Panel setup
-
"
Review the setup configuration for the control panel.
Activations
-
"
Review the cause & effect strategy for a specified Fire zone,
Device, plant Zone or Output group.
Fault codes
-
"
View the list of engineers fault codes.
Logon faults
-
"
View new devices that have not currently been accepted
onto the system. Adding or removing devices from the
detection loop will produce a logon fault.
Config faults
-
"
Download configuration device faults. Devices that do not
match the VIPER upload download site file.
Loop quantity
-
"
View the total number of devices present on each detection
loop.
Database
-
"
Not applicable
Check EOC indexs
-
"
Not applicable
Table 7: List Menu