page 42 — MLT20 seRIes LIgHT TOWeR • OpeRaTIOn ManuaL — Rev. #0 (01/18/13) 
trOubleShOOting
Table 5.  Lamp Troubleshooting
symptom
possible Cause
solution
Lamp will not start.
Lamp Burned Out?
Test the lamp in a fixture which is operating properly. 
Replace if necessary.
Lamp Loose in Socket?
Inspect lamp base to see if there is arcing at center 
contact button. Tighten lamp snugly. Check socket for 
damage. Replace if defective.
Lamp Plugs Not Tight?
Check plug and receptacle. Tighten if loose.
Defective Ballast?
Interchange ballast plugs in generator enclosure. 
If lamp starts, replace ballast. Check ballast wiring 
against diagram. Check for swollen capacitor, charred 
wiring, core and coil or other signs of excessive heat.
Low Voltage?
Check line voltage at ballast input. Voltage should 
be within 10% of nameplate rating when operating 
at normal load. Increase supply voltage or remove 
external load.
Improper Ballast?
Proper HID lamps will perform erratically or fail to 
start on an improper ballast. The ballast nameplate 
data must agree with the line voltage and lamp used. 
Improper ballast causes lamp failure. Note:  Mercury 
lamps of the same wattage will operate properly on 
Metal Halide ballasts.
Improper Lamp Operating 
Position (Metal Halide only)?
Operating position should agree with the lamp tech. 
A BU-HOR lamp can be operated base up vertical to 
and including the horizontal and a BD can be operated 
base down vertical to, approaching, but not including 
the horizontal. A lamp operated beyond the specified 
position may not start.
Lamp has been Operating: Cool 
Down Time Insufficient?
HID lamps (High Pressure Sodium, Metal Halide, 
Mercury Vapor) require from 4 to 8 minutes cool-down 
time before restarting. Switch off breaker and allow 
lamp to cool.
Lamp flickers and goes 
out intermittent or 
cycling.
Improper Ballast?
Improper ballasting can cause flickering or erratic 
operation. In the start-up period the lamp may ignite, 
start to warm up and then extinguish (cycle).
New Lamp?
Under certain conditions new lamps may "cycle". 
Usually after 3 tries to start at 30 to 60 second 
intervals, lamps will stabilize and operate satisfactorily.
Defective Lamp?
Replace lamp.