Fiber Driver
®
 EM316EDFA User Guide
 
 
P/N 1294008-001 Rev D2 
 
31 
 
 
 
 
5.2.6.4 “port description” 
 
 
As with a module at the slot level, a descriptive name may be applied to each port. An 
example of the description command at the port level is shown below. 
 
 
 
 
fiberdriver(port/1.3.1)# description EDFA-port1 
fiberdriver(port/1.3.1)# show 
Port: 1.3.1 
Name: EDFA-port1 
 
Enable: enable 
  Link: no Signal 
 
Connector: fo SC  Medium: single Mode 
TxPower(dBm): -15.26 
      DDiags: Alarm   Temp(C): 23  Supply(V): 3.28 
 
Alarm Cause: TX Loss of Signal Alarm (tx -15.26dBm) 
 
Gain desired(dB): 25 
        Gain(dB): 24.76 
 
fiberdriver(port/1.3.1)#