Modine Manufacturing GAS-FIRED HEATERS PD 사용자 설명서

다운로드
페이지 28
40
926
1070
3/4
C61
2.0
1130
3/4
C61
1.5
45
823
1020
1/2
C61
2.5
1085
3/4
C61
2.0
50
741
985
1/2
C61
3.0
1050
1/2
C61
2.5
55
673
955
1/2
C61
3.5
1025
1/2
C61
2.5
60
617
935
1/3
C1
3.5
1000
1/2
C61
3.0
65
570
915
1/3
C1
4.0
985
1/3
C1
3.0
70
529
905
1/3
C1
4.0
975
1/3
C1
3.0
40
1389
955
1
C91
3.5
1010
1
C91
3.0
45
1235
920
3/4
C187
1.0
985
1
C91
3.0
1045
1
C91
2.5
50
1111
895
3/4
C187
1.5
960
3/4
C187
0.5
1025
1
C91
2.5
55
1010
880
3/4
C187
2.0
945
3/4
C187
1.0
1010
3/4
C187
0.0
60
926
865
1/2
C187
2.0
940
3/4
C187
1.0
1005
3/4
C187
0.0
65
855
855
1/2
C187
2.0
930
3/4
C187
1.0
1000
3/4
C187
0.0
70
794
850
1/2
C187
2.0
925
3/4
C187
1.0
995
3/4
C187
0.0
40
1852
1095
1C
C91
2.0
1145
1
C91
1.0
45
1646
1035
3/4
C91
2.5
1090
1
C91
2.0
1140
1
C91
1.5
50
1481
985
3/4
C91
3.0
1045
3/4
C91
2.5
1100
3/4
C91
2.0
55
1347
955
1/2
C91
3.5
1015
3/4
C91
3.0
1070
3/4
C91
2.0
60
1235
925
1/2
C91
4.0
990
3/4
C91
3.0
1050
3/4
C91
2.5
65
1140
905
1/2
C91
4.0
970
1/2
C91
3.5
1030
3/4
C91
2.5
70
1058
890
1/2
C91
4.0
955
1/2
C91
3.5
1020
1/2
C91
2.5
40
2315
1080
1 1/2 C201
3.0
1125
1 1/2 C201
2.5
1165
1-1/2
C201
1.5
45
2058
1010
1
C190
3.0
1060
1
C190
2.0
1105
1
C190
1.5
50
1852
960
3/4
C199
3.5
1010
3/4
C199
3.0
1055
1
C190
2.5
55
1684
920
3/4
C199
4.0
970
3/4
C199
3.0
1020
3/4
C199
2.5
60
1543
890
1/2
C211
1.5
940
3/4
C199
3.5
995
3/4
C199
3.0
65
1425
865
1/2
C211
2.0
920
1/2
C211
1.0
970
3/4
C199
3.0
70
1323
845
1/2
C211
2.5
900
1/2
C211
1.5
955
1/2
C211
0.5
40
2778
750
1
C38
1.5
45
2469
715
1
C38
2.0
755
1
C38
1.5
50
2222
685
3/4
C38
2.5
730
3/4
C38
2.0
55
2020
665
3/4
C38
3.0
715
3/4
C38
2.0
60
1852
650
1/2
C96
1.5
700
3/4
C38
2.5
65
1709
640
1/2
C96
1.5
690
3/4
C38
2.5
70
1587
630
1/2
C96
2.0
680
1/2
C96
1.0
40
3241
970
2
C80
2.5
1005
2
C80
1.5
1035
2
C80
1.0
45
2881
900
1 1/2 C193
1.0
935
1 1/2 C193
0.5
970
2
C80
2.5
50
2593
845
1
C192
2.5
885
1 1/2 C193
1.5
920
1-1/2
C193
0.5
55
2357
805
1
C192
3.0
845
1
C192
2.5
880
1
C192
1.5
60
2160
770
3/4
C192
3.5
815
3/4
C192
2.5
855
1
C192
2.0
65
1994
745
3/4
C192
3.5
790
3/4
C192
3.0
830
3/4
C192
2.5
70
1852
725
1/2
C96
0.0
770
3/4
C192
3.5
815
3/4
C192
2.5
40
3704
615
1-1/2 C105
4.0
650
1 1/2 C105
3
685
45
3292
590
1
C16
1.0
625
1 1/2 C105
4
660
50
2963
570
3/4
C16
1.5
610
1
C16
0.5
645
55
2694
555
3/4
C16
1.5
595
1
C16
0.5
635
60
2469
545
3/4
C16
2.0
590
3/4
C16
1
630
65
2279
540
3/4
C16
2.0
585
3/4
C16
1
625
70
2116
535
1/2
C101
0.5
580
3/4
C16
1
625
40
4630
750
2
C108
2.5
775
2
C108
2
45
4115
695
1 1/2 C105
2.0
725
2
C108
3
755
2
C108
2.5
50
3704
660
1 1/2 C105
3.0
690
1 1/2 C105
2
720
1 1/2
C105
1.0
55
3367
630
1
C205
2.0
665
1 1/2 C105
3
695
1 1/2
C105
2.0
60
3086
605
1
C205
2.0
645
1
C205
0.5
680
1
C205
1.0
65
2849
590
3/4
C205
2.5
630
1
C205
2
665
1
C205
1.0
70
2646
575
3/4
C205
3.0
615
3/4
C205
2.0
655
1
C205
1.0
40
45
4938
865
3
C111
2.0
890
3
C111
1.5
915
3
C111
1.0
50
4444
805
2
C108
1.0
830
2
C108
0.5
860
3
C111
2.0
55
4040
760
1 1/2 C106
2.5
785
2
C108
1.5
815
2
C108
1.0
60
3704
720
1 1/2 C106
3.5
750
1 1/2 C106
2.5
780
1 1/2
C106
1.5
65
3419
690
1 1/2 C106
4.0
720
1 1/2 C106
3.5
750
1 1/2
C106
2.5
70
3175
660
1
C205
1.0
695
1
C205
0.5
725
1 1/2
C106
3.0
40
6481
1070
5
C207
0.5
1095
5
C207
0.0
45
5761
975
5
C207
2.0
1000
5
C207
1.5
1025
5
C207
1.5
50
5185
905
3
C111
1.0
930
3
C111
0.5
955
3
C111
0.0
55
4714
845
3
C111
2.5
870
3
C111
2.0
900
3
C111
1.0
60
4321
800
2
C210
3.5
825
2
C210
3.0
855
2
C210
2.5
65
3989
760
1 1/2 C105
0.0
790
1 1/2 C100
4.0
815
2
C210
3.0
70
3704
725
1 1/2 C105
1.0
755
1 1/2 C105
0.0
785
1-1/2
C100
4.0
40
-
-
-
-
-
-
-
-
-
-
-
-
-
45
6584
1010
5
C207
1.5
1035
5
C207
1.0
1055
5
C207
0.5
50
5926
935
5
C207
3.0
955
5
C207
2.5
980
5
C207
2.0
55
5387
870
3
C111
2.0
895
3
C111
1.0
920
3
C111
0.5
60
4938
820
3
C111
3.0
850
3
C111
2.5
875
3
C111
2.0
65
4558
780
2
C210
4.0
805
2
C210
3.5
835
2
C210
2.5
70
4233
745
1 1/2 C105
0.5
775
2
C210
4.0
800
2
C210
3.5
19
Filters
For blower units with enclosure and filter, add
the following static pressures to the static
pressure determined by the system designer
for total external static pressure.
PERFORMANCE DATA - CONTINUED
BD 50
0.1" W.C.
BD 75
0.2" W.C.
BD 100
0.2" W.C.
BD 125
0.3" W.C.
BD 150
0.1" W.C.
BD 175
0.2" W.C.
BD 200
0.1" W.C.
BD 250
0.2" W.C.
BD 300
0.2" W.C.
BD 350
0.2" W.C.
BD 400
0.2" W.C.
Models With or Without Blower Enclosure ➀ ➁ ➂ ➃ ➄
0.5 Static Air Pressure
0.6 Static Air Pressure
0.7 Static Air Pressure
Temp
Sheave
Sheave
Sheave
Model
Rise
Airflow RPM
HP
Drive
Turns
RPM
HP
Drive
Turns RPM
HP
Drive
Turns
No.
(°F)
(cfm)
No.
Open
No.
Open
No.
Open
BD
50
BD
75
BD
100
BD
125
BD
150
BD
175
BD
200
BD
250
BD
300
BD
350
BD
400
Shaded area indicates the unit’s standard motor &
standard drive arrangement. For operation outside
the shaded area, specify motor Hp and drive
number.
Outputs shown are for elevations up to 2000'. For
elevations over 2000’, output needs to be reduced
4% for each 1000' above sea level. (Does not apply
in Canada - see rating plate)
Sheave turns open are approximate. For proper
operation, check blower rpm.
Mounting height and throw for BD models (w/o duct-
work or nozzles and at an airflow yielding a 55°
temperature rise), are the same as those listed on
page 12 for equivalent PD models.
Rpm setting shown in bold type indicate factory
settings and standard drives.
Data for use with filters only
1/2
1/2
1/3
3/4
C61
C61
C1
C187
C187
3/4
1
C91
3/4
C91
C91
3/4
3/4
3/4
1
1/2
1/2
3/4
1/2
1/2
3/4
3/4
1-1/2
1
3/4
1-1/2
5
3
1-1/2
5
3
C199
C211
3/4
1/2
C38
C96
C192
C16
C105
C205
C106
C207
C111
C105
C207
C111
C207
C111
C210
C210
C207
C111
C111
C210
C207
C106
C108
C205
C105
C108
C16
C105
C192
C193
C38
C211
C199
C111
C111
C205
C105
C106
3/4
3/4
1-1/2
1-1/2
1
3/4
2
1-1/2
1
2
1-1/2
5
3
1-1/2
5
3
2
5
1-1/2
3
1-1/2
3/4
1
2
C80
C199
C190
C192
1
3/4
1
3
2
3
2
1
1
C187
C91
C91
1
3/4
C1
1/3
3/4
1/2
HP & Drive
HP & Drive to ORDER
from this Catalog
from Price List ➀
1/4 - C182
=
1/4 - C194
BD 50
1/4 - C183
=
1/4 - C195
1/3 - C1
=
1/3 - C61
1/4 - C184
=
1/4 - C196
BD75
1/4 - C185
=
1/4 - C186
1/3 - C185
=
1/3 - C186
1/4 - C200
=
1/4 - C208
BD100
1/4 - C90
=
1/4 - C92
1/3 - C90
=
1/3 - C92
1/4 - C188
=
1/4 - C189
1/3 - C188
=
1/3 - C189
BD125
1/3 - C202
=
1/3 - C211
1 1/2 - C201
=
1 1/2 - C209
1/4 - C191
=
1/4 - C197
BD150
1/3 - C197
=
1/3 - C197
1/3 - C95
=
1/3 - C96
1/3 - C95
=
1/3 - C96
BD175
1 1/2 - C193
=
1 1/2 - C198
1/4 - C212
=
1/4 - C213
1/3 - C212
=
1/3 - C213
BD200
1/3 - C102
=
1/3 - C101
1 1/2 - C105
=
1 1/2 - C180
1/3 - C203
=
1/3 - C204
BD250
1 1/2 - C105
=
1 1/2 - C180
BD300
1 1/2 - C106
=
1 1/2 - C108
1 1/2 - C105
=
1 1/2 - C180
BD350
1 1/2 - C100
=
1 1/2 - C210
BD400
1 1/2 - C105
=
1 1/2 - C180
Important: Note for 575V Only
Performance is the same; motor sheave can just
accomodate larger shaft.