TROUBLESHOOTING GUIDE
Possible Cause
Possible Remedy
2a. Gas valve in off
2a. Turn to on position.
off position.
2b. System in lock-out
2b. Reset system.
mode.
2c. Cracked or broken
2c. Replace sensor.
sensor ceramic.
2d. Defective or loose
2d. Correct or replace.
connections to flame
sensor or flame
sensor lead.
2e. Incorrect gas
2e. Check and adjust if necessary to
pressure.
manufacturer’s recommendations
and replace if necessary.
2f.
Insufficient current
2f.
Check current according to
signal from flame
manufacturer’s recommendations
sensor.
and replace if necessary.
2g. Incorrect or loose
2g. Check wiring.
wiring.
2h. Poor ground to
2h. Check grounding means.
ignition control.
2i.
No power to ignition
2i.
Check voltage to controller and gas
controller or gas
valve.
valve.
2j.
Loose limit control
2j.
Check connections.
connections or
Replace limit control if necessary.
defective unit.
2k. Defective or plugged
2k. Inspect gas valve regulator.
gas valve regulator.
Replace if necessary.
2l.
Defective thermostat
2l.
Calibrate thermostat or replace if
or thermostat out
necessary.
of calibration.
2m. Thermostat heat
2m. Check anticipator setting and correct
anticipator
if necessary.
incorrectly set.
2n. Defective ignition
2n. Replace.
controller.
Possible Cause
Possible Remedy
3a. Flame sensing
3a. Check flame sensing rod, sensor
circuit failure.
ceramic, sensor lead and
connections for damage or loss of
continuity. Replace defective
elements.
3b. Soot on sensing rod.
3b. Clean off soot and adjust pilot to
smaller size.
3c. Blockage in heat
3c. Clean heat exchanger.
exchanger.
Determine cause and correct.
3d. Blockage in main
3d. Clean or replace orifice.
burner orifice.
Possible Cause
Possible Remedy
4a. Faulty thermostat
4a. Check thermostat and anticipator
or improper heat
setting. Replace if defective.
anticipator setting.
4b. Defective ignition
4b. Replace.
controller.
4c. Defective gas control. 4c. Replace.
27
2. Pilot lights, main burner will not light.
3. Burner shuts down before thermostat is satisfied.
4. Burner fails to shut off after thermostat is satisfied.
For Service . . .
If a qualified service person cannot solve the problem, consult
your local gas company or local Modine representative.
When servicing, repairing or replacing parts on these units
always give the complete Model Number (which includes power
code/control code) and Serial Number from the unit rating plate.
RATING PLATE IDENTIFICATION
When servicing, repairing or replacing parts on these units
always give the complete Model Number, Power Code Number,
Control Code Number and Serial Number from the unit rating
plate. The sample below shows what these numbers mean.
P - Propeller Unit
B - Blower Unit
S -  Separated
Combustion
H - High Efficiency
F - Unit equipped with
intermittent pilot ignition
V - Unit equipped with
intermittent pilot ignition
and concentric vent
compatible.
MBH Input
150 - 150,000 Btu/hr input
170 - 170,000 Btu/hr input
225 - 225,000 Btu/hr input
etc.
Heat Exchanger Type
A - Aluminized
S - Stainless Steel
Control Code Type
30 - 115v/25v intermittent 
pilot ignition, 100% 
Shut-Off with continuous 
retry, natural gas
31 - 230v/25v intermittent 
pilot ignition, 100% 
Shut-Off with continuous 
retry, natural gas
etc.
Power Code
01 - 115v/60Hz/1φ
02 - 230v/60Hz/1φ
etc.
P S H 2 8 0 A V 0 1 3 0
MODEL NUMBER DESIGNATIONS
Motor Vendor Code
01 -
Century
05 -
Universal
etc.
Fan or Blower
Vendor Code
01 - Revcor
08 - Brookside
etc.
Series Identity Number
Identifies which series of controls
were furnished on the unit.
Sequence
Number
Year of Manufacture
96 -
1996
97 -
1997
etc.
Week of Manufacture
01 -
1
st
week of year
26 -
26
th
week of year
etc.
0 1 0 1 2 0 1 0 1 9 7 1 0 0 0
SERIAL NUMBER DESIGNATIONS
RATING PLATE
Power Code
Control Code
SERIAL NUMBER
MODEL NUMBER
01122010195
PSH280AF
01
30