4 - 10
4.4.2 Batch monitoring of device values
4  CREATING PROGRAM IN ST LANGUAGE
GX Works2
4.4.2
Batch monitoring of device values
For the Batch monitoring of device values procedure, refer to the following. 
5.
Turn ON inputs X0, X1 and X2 in the programmable controller, and check the following 
operations.
You can turn ON inputs X0, X1 and X2 using the test operation above.
• When X0 turns ON, the programmable controller turns ON Y10, and then turns OFF Y10 1 
second later.
• When X1 turns ON, the programmable controller transfers K10 to VAR1 (device: D0). 
• When X2 turns ON, the programmable controller transfers K20 to VAR1 (device: D0).
6.
Select [Online] 
 [Monitor] 
 [Stop 
Monitoring] to stop (pause) the monitor status 
on the POU_01 [PRG] Program [ST] screen.
You can click 
 (Stop Monitoring) to reset the  
POU_01 [PRG] Program [ST] screen. 
7.
Set the programmable controller CPU to STOP.  
Set the RUN/STOP switch on the programmable 
controller CPU to "STOP".
You can switch the programmable controller status 
between "RUN" and "STOP" using remote 
operation.  
 
Y10 remains ON
for 1 second.
X0 turns ON.
VAR1 becomes "10".
X1 turns ON.
VAR1 becomes "20".
X2 turns ON.