PATENTS PENDING
43
 
11921 Slauson 
A
ve.  Santa Fe Springs, CA.  90670  (800) 227-41
16  F
AX (888) 771-7713
LH SIDE OF LIFT
FIG. 43-1A
ADJUSTING SWITCH
FIG. 43-1B
THRESHOLD 
PLATE
THRESHOLD
WARNING BEACON
4. Turn the MAT switch adjustment screw 
(FIGS. 43-1B and 43-2) clockwise until 
threshold warning alarm and beacons acti-
vate (FIG. 43-1A). Then, turn adjustment 
screw counter-clockwise (FIG. 43-2) ap-
proximately 1-1/2 turn. Warning alarm and 
beacons should turn off. 
5. Step on threshold plate. Warning alarm 
and beacons should activate. If the warning 
alarm and beacons do not activate, slightly 
turn adjustment screw (FIGS. 43-1B and 
43-2)
 clockwise. Repeat until warning 
alarm and beacons activate when stepping 
on threshold plate and deactivate stepping 
off threshold plate. 
MAT SWITCH ADJUSTMENT SCREWS
FIG. 43-2
CW - UNTIL ALARM & 
BEACONS TURN ON
1-1/2 TURN CCW - ALARM 
& BEACONS TURN OFF
BASE 
PLATE
ADJUSTMENT 
SCREW
THRESHOLD
WARNING ALARM