RF1200W Copper Water Piping Instructions
 
Tools Required: 
 
Small cup or pail 
 
Utility knife 
 
Paper towel 
 
Adjustable wrenches (2) 
 
Braze rod 
 
Torch 
 
Flat blade screwdriver 
 
Phillips screwdriver 
 
Hammer 
 
3/8” OD swaging tool 
 
Tubing cutter 
 
Deburring tool 
 
Sharpie marker 
 
Wet sponge/rag 
 
Instructions: 
1.  Disconnect power, condenser supply/drain, potable water supply/drain 
2.  Remove front, top and RH panels.  Remove rear grille 
3.  Loosen both hose clamps on condenser hoses.  Remove hose from condenser outlet (top) 
4.  With cup/pail at the ready, remove hose from condenser inlet (bottom).  Drain condenser and hose 
5.  Loosen both hose clamps on water regulating valve.  Using utility knife, cut both hose ends to facilitate 
hose removal from barbed fittings on valve 
6.  Remove both hoses and discard 
7.  Remove 2 screws from gray plastic drain manifold (some machines have brass winged adapter) on 
back panel; discard manifold 
8.  Remove 2 screws from condenser inlet fitting on back panel; save screws.  Tilt top of fitting toward 
inside of machine and remove fitting and hose.  Discard fitting and hose 
9.  Remove 2 screws from black plastic drain manifold on back panel; save screws.  Temporarily move 
black manifold w/hose attached to other side of gear motor 
10. Disconnect wires from potable water solenoid valve, then remove 2 screws from solenoid valve on back 
panel; save screws.  IMPORTANT – Make sure solenoid valve hose is routed ABOVE the evaporator 
water inlet hose 
11. With adjustable wrenches, remove top barbed fitting from water regulating valve.  Then slightly loosen 
bottom barbed fitting.  Remove 2 screws from water regulating valve bracket; discard screws.  Remove 
bottom barbed fitting.  Discard barbed fittings and bracket 
12. Clean residual Teflon tape from inside threads on water regulating valve 
13. Install flat bracket from kit onto inner most square hole in back panel.  Bracket must be on outside of 
back panel 
14. From kit, find two 3/8” brass adapters (Male BSPP x Female NPT) and two adapter seals.  On 1st 
adapter, apply Teflon tape to male BSPP threads.  From outside of the machine, with Teflon taped end 
1
st
, insert 1
st
 adapter thru flat bracket.  Thread on one adapter seal over Teflon taped end of 1
st
 
adapter 
15. Orient water regulating valve so flow arrow is pointing into machine.  Thread 1
st
 adapter into valve 
inlet.  Tighten adapter securely to valve 
16. Apply Teflon tape to 2
nd
 adapter and thread on 2
nd
 adapter seal.  Install into outlet of water regulating 
valve.  Tighten adapter securely to valve 
17. Apply Teflon tape to NPT threaded end (not flared end) of 45
 brass elbow.  Thread taped end into 
adapter on water regulating valve outlet.  Tighten elbow so 45
 flare is pointing to water condenser