11. Set the CRC
field to
y
12. The Idle Code default is 11111111.
13. The DCP/Analog Bearer Capability default is 3.1 kHz.
14. Set the
M
MI Cabling Board
field to
xxxxx
(where xxxxx is the location of
the TN787 MMI circuit pack recorded in step 2). This must be the slot for
port B of the Y-cable.
port B of the Y-cable.
15.
The
MMI Interface
field
ESM
appears.
Signaling-Group form, page 1
Screen 18.
Signaling-Group Form (Page 1 of 5)
1. Enter
add signaling-group next
and the signaling-group form appears.
2. Change
A
ssociated Signaling field to
y
.
3. Change Primary D-Channel Port field to
xxxx16
(where xxxx is the
address of the TN2207 PRI circuit pack, for example: 1B0516).
4. The Max Number of NCA TSC default is
0.
5. The Max Number of GA TSC default is
0.
6. Trunk Group for NCA TSC ____ (leave blank)
7. Trunk Group for Channel Selection____ (leave blank)
8. Logoff the terminal and then log back on the terminal to view your
changes.
Troubleshooting.
To determine ESM link status enter the following commands
from the system administration terminal:
1. Status esm
2. Status signaling-group
3. List MMI
change signaling-group 6 Page 1 of 5
SIGNALING GROUP
Group Number: 6
Associated Signaling? y Max number of NCA TSC: 0
Primary D-Channel: 01C0916 Max number of CA TSC: 0
Trunk Group for NCA TSC:
Trunk Group for Channel Selection:
Supplementary Service Protocol: a
SIGNALING GROUP
Group Number: 6
Associated Signaling? y Max number of NCA TSC: 0
Primary D-Channel: 01C0916 Max number of CA TSC: 0
Trunk Group for NCA TSC:
Trunk Group for Channel Selection:
Supplementary Service Protocol: a