SCH Collectors Installation & Operation Manual
4
SCH Collector
7
1
7
2
4
8
6
3
5
6. Inlet 
connection
 
Copper pipes, .86" diameter.
7. Outlet 
connection
 
Copper pipes, .86" diameter.
8. Absorber 
coils
 
10 mm copper, serpentine arrangement.
9. Hydraulic 
connection 
kit
 
Connection set with stainless steel corrugated pipe.  For connecting 
 
the collector supply and return to the riser.  The corrugated pipes 
 
are available in kits with 2 x 6'-7" or 2 x 13'1" length including 
 
sensor well and plug.
10. Sensor well
 
For measuring the collector outlet temperature directly in 
 
the fluid.  The sensor well can be installed on the outlet connection 
 
as shown on the collector label.  The sensor must be inserted up to 
 
the end of the sensor well.
11. Plug
 
This plug is used on the end collector of each array to complete the 
 
water flow path.
How it works...
1. Housing
 
Powder coated (RAL7016)aluminum frame structure with 
 
PU rigid foam and an aluminum rear wall.
2. Cover
 
Prismatic solar safety glass, .15" thick, for maximum light 
 transmission.
 
3. Insulation
 
.76" heat resistant, special PU rigid foam and 1.57" mineral 
 
wool with high pressure resistance, emission free, non-
 flammable. 
4. Absorber
 
Full surface absorber, laser welded with highly-selective PVD 
 
coating (PVD = Physical Vapor Deposition), serpentine flow.
 
5. Collector 
seal
 
Aluminum profile system with double temperature and UV-
 
resistant silicone seals, emission free. 
1  
Introduction
10
9