SPECIFICATIONS
 - Optima 2 FS  
 
PAGE 34 
Flue Size 
 
 
3”  / 76mm Rear 
 
Width, Overall 
 
 
23” / 584mm 
 
Depth, Overall   
 
22 3/4” / 578mm 
Depth, Overall w / 3” tee   
28 1/2” / 724mm 
 
Height 
   28 
5/8” 
727mm 
 
Floor to Rear  
Flue Center 
 
 
11 1/4” / 286mm 
 
Facing back of unit, 
outside edge of left side 
to center of rear 
flue outlet center   
 
6 1/2” / 165mm 
 
Floor to Rear 
Outside Air Inlet 
Located on center- 
line of pedestal  back   
5” / 127mm 
 
Facing back of Unit 
outside edge of right side 
to center of air inlet 
 
11 1/2” / 292mm 
 
Floor Protection  
+  Front and Sides: 6”/152mm 
Requirements 
 
Back: Up to 6” / 152mm 
 
Standard Features 
 
Fastfire Self Igniter 
 
Wall Thermostat (wire  in-
cluded) 
 
Hopper Capacity 
 
55 lbs. 
 
Burn time 
♦  15-37 hours  
 
Fuse, Control Board 
 
5 Amp, 250 volt, 3AG * 
Fuse, Igniter 
 
6 Amp, 125 volt * 
 
Heat Input (BTU’s per hour) 
♦  13,000-32,000 BTU / hr 
Overall Efficiency 
 
75-81% 
 
Emissions 
♦  0.4 gr / hr (varies w/size 
and type of fuel) EPA ex-
empt. 
 
Shipping Weight 
 
215 lbs. 
 
Room Air Blower 
 
150 CFM; .8 Amps,  
2175 rpm 
 
Auger Motor  
 
1 RPM; .4 Amps 
 
Exhaust Blower 
 
95 CFM: 1.0 Amps, 
2880 rpm 
 
Fastfire 
Igniter 
  4.35 
Amps, 
 
Options 
 
Nickel or Gold Trim Kits 
4” Quick Disconnect 
Log Set 
BACK VIEW 
 
 
 
SIDE VIEW 
 
 
Note: Dimensions shown are approximations only (+/- ¼”) 
 
Non-combustible floor protection is required (see 
Floor Protection, page 5). When installed at clear-
ances less than 6”, the floor protector is only re-
quired to extend to the wall. 
 
  Fuel delivery and burn times will vary depending 
on size and type of fuel used. Estimated heat in-
put based on fuel value of 8400 BTU per lb. 
 
Fuses are rated as fast blow.
28 1/2" 
w/clean-out tee 
22 3/4" 
23" 
28 5/8" 
11 ¼"
6 ½"
11 1/2" 
8 ¾"
5 1/8"