Intel SR1630BC 사용자 설명서

다운로드
페이지 58
Intel® Server System SR1630BC TPS 
Front Control Panel  
 
Intel order number E44588-005 Revision 
1.5 
 
26 
 
Color 
State 
Criticality 
Description 
Amber Blink 
Non-critical 
Non-fatal alarm – system is likely to fail: 
ƒ CATERR 
asserted. 
ƒ Critical 
temperature threshold asserted. 
ƒ 
Critical voltage threshold asserted. 
ƒ 
Critical fan threshold asserted. 
ƒ 
VRD hot asserted. 
ƒ 
SMI Timeout asserted.
 
Amber Solid 
on 
Critical, non-
recoverable 
Fatal alarm – system has failed or shutdown: 
ƒ CPU 
Missing. 
ƒ Thermtrip 
asserted. 
ƒ 
Non-recoverable temperature threshold asserted. 
ƒ 
Non-recoverable voltage threshold asserted. 
ƒ 
Power fault / Power Control Failure. 
ƒ 
Fan redundancy lost, insufficient system cooling. This does not 
apply to non-redundant systems. 
ƒ 
Power supply redundancy lost, insufficient system power. This does 
not apply to non-redundant systems. 
ƒ 
This state will also happen when AC power is first applied to the 
system. This indicates that the BMC is booting. 
 
6.1.3 
Drive Activity LED 
The drive activity LED on the front panel indicates drive activity from the onboard hard disk 
controllers.